Your browser doesn't support javascript.
loading
Is greater than 145{degrees} of deep knee flexion under weight-bearing conditions safe after total knee arthroplasty?: a fluoroscopic analysis of Japanese-style deep knee flexion.
Niki, Y; Takeda, Y; Udagawa, K; Enomoto, H; Toyama, Y; Suda, Y.
Afiliação
  • Niki Y; Department of Orthopaedic Surgery, Keio University, School of Medicine, 35 Shinanomachi, Shinjuku, Tokyo 160-8582, Japan.
Bone Joint J ; 95-B(6): 782-7, 2013 Jun.
Article em En | MEDLINE | ID: mdl-23723272
ABSTRACT
We investigated the characteristics of patients who achieved Japanese-style deep flexion (seiza-sitting) after total knee replacement (TKR) and measured three-dimensional positioning and the contact positions of the femoral and tibial components. Seiza-sitting was achieved after surgery by 23 patients (29 knees) of a series of 463 TKRs in 341 patients. Pre-operatively most of these patients were capable of seiza-sitting, had a lower body mass index and a favourable attitude towards the Japanese lifestyle (27 of 29 knees). According to two-/three-dimensional image registration analysis in the seiza-sitting position, flexion, varus and internal rotation angles of the tibial component relative to the femoral component had means of 148° (SD 8.0), 1.9° (SD 3.2) and 13.4° (SD 5.9), respectively. Femoral surface contact positions tended to be close to the posterior edge of the tibial polyethylene insert, particularly in the lateral compartment, but only 8.3% (two of 24) of knees showed femoral subluxation over the posterior edge. The mean contact positions of the femoral cam on the tibial post were located 7.8 mm (sd 1.5) proximal to the lowest point of the polyethylene surface and 5.5 mm (SD 0.9) medial to the centre of the post, indicating that the post-cam contact position translated medially during seiza-sitting, but not proximally. Collectively, the seiza-sitting position seems safe against component dislocation, but the risks of posterior edge loading and breakage of the tibial polyethylene post remain.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fluoroscopia / Amplitude de Movimento Articular / Suporte de Carga / Osteoartrite do Joelho / Recuperação de Função Fisiológica / Articulação do Joelho Tipo de estudo: Observational_studies / Risk_factors_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged País/Região como assunto: Asia Idioma: En Revista: Bone Joint J Ano de publicação: 2013 Tipo de documento: Article País de afiliação: Japão

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fluoroscopia / Amplitude de Movimento Articular / Suporte de Carga / Osteoartrite do Joelho / Recuperação de Função Fisiológica / Articulação do Joelho Tipo de estudo: Observational_studies / Risk_factors_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged País/Região como assunto: Asia Idioma: En Revista: Bone Joint J Ano de publicação: 2013 Tipo de documento: Article País de afiliação: Japão