The U.S. EPA's in vitro bioaccessibility (IVBA) method 9200.1-86 defines a validated analytical procedure for the determination of lead bioaccessibility in contaminated soils. The method requires the use of a custom-fabricated extraction device that uses a heated water bath for sample incubation. In an effort to improve ease of use, increase sample throughput, and reduce equipment acquisition and maintenance costs, an alternative low-cost, commercially available extraction device capable of sample incubation via heated air and end-over-end rotation was evaluated. An intra-laboratory study was conducted to compare lead bioaccessibility values derived using the two extraction devices. IVBA values were not statistically different (α = 0.05) between the two extraction devices for any of the soils (n = 6) evaluated in this study, with an average difference in mean lead IVBA of 0.8% (s.d. = 0.5%). The commercially available extraction device was able to generate accurate lead IVBA data as compared to the U.S. EPA's expected value for a National Institute of Standards and Technology standard reference material soil. The relative percent differences between high and low IVBA values for each soil, a measure of instrument precision, were also not statistically different (α = 0.05) between the two extraction devices. The statistical agreement of lead IVBA values observed using the two extraction devices supports the use of a low-cost, commercially available extraction device as a reliable alternative to a custom-fabricated device as required by EPA method 9200.1-86.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Solo / Poluentes do Solo / Monitoramento Ambiental / Chumbo Tipo de estudo: Evaluation_studies / Health_economic_evaluation Idioma: En Revista: Environ Sci Process Impacts Ano de publicação: 2013 Tipo de documento: Article País de afiliação: Estados Unidos País de publicação: Reino Unido
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Solo / Poluentes do Solo / Monitoramento Ambiental / Chumbo Tipo de estudo: Evaluation_studies / Health_economic_evaluation Idioma: En Revista: Environ Sci Process Impacts Ano de publicação: 2013 Tipo de documento: Article País de afiliação: Estados Unidos País de publicação: Reino Unido