Your browser doesn't support javascript.
loading
New methodological approach to improve reproducibility of brachial artery flow-mediated dilatation.
Kanahara, Masaaki; Harada, Haruhito; Katoh, Atsushi; Ikeda, Hisao.
Afiliação
  • Kanahara M; Department of Medical Laboratory Science, Faculty of Health Sciences, Junshin Gakuen University, Fukuoka, Japan.
Echocardiography ; 31(2): 197-202, 2014 Feb.
Article em En | MEDLINE | ID: mdl-23909753
ABSTRACT

BACKGROUND:

Measurement of flow-mediated dilation (FMD) is well known as a noninvasive method for an assessment of vascular endothelial function. However, the reproducibility is a major issue of FMD measurement. The purpose of this study is to examine the reproducibility of the new FMD measurement with medial epicondyle method.

METHODS:

First, to evaluate the variability of the brachial artery diameter, 23 volunteers recruited from 32 healthy volunteers were examined for a brachial artery diameter at rest using with FMD equipment. Second, to evaluate the reproducibility of the FMD measurement, all volunteers underwent the FMD measurement, which was repeated at 2-week interval using the traditional method and the medial epicondyle method. The reproducibility in both methods was evaluated by 2 independent observers who measured on the same subject to assess the inter-observer reproducibility, and 1 observer who measured the same subject twice to assess the intra-observer reproducibility regarding the baseline value of arterial diameter and FMD.

RESULTS:

The variability of brachial artery diameter was 0.57 ± 0.27 mm in 23 healthy volunteers. In the study of inter- and intra-observer reproducibility, 2 parameters including intra-class correlation coefficient and Pearson's correlation coefficient by medial epicondyle method are superior to those by traditional method.

CONCLUSIONS:

These results suggest that medial epicondyle methodological approach to measure FMD is superior to traditional method.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Artéria Braquial / Endotélio Vascular / Ecocardiografia / Interpretação de Imagem Assistida por Computador / Aumento da Imagem / Pontos de Referência Anatômicos Tipo de estudo: Diagnostic_studies Limite: Adult / Female / Humans / Male Idioma: En Revista: Echocardiography Assunto da revista: CARDIOLOGIA / DIAGNOSTICO POR IMAGEM Ano de publicação: 2014 Tipo de documento: Article País de afiliação: Japão

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Artéria Braquial / Endotélio Vascular / Ecocardiografia / Interpretação de Imagem Assistida por Computador / Aumento da Imagem / Pontos de Referência Anatômicos Tipo de estudo: Diagnostic_studies Limite: Adult / Female / Humans / Male Idioma: En Revista: Echocardiography Assunto da revista: CARDIOLOGIA / DIAGNOSTICO POR IMAGEM Ano de publicação: 2014 Tipo de documento: Article País de afiliação: Japão