Coiling of large and giant aneurysms: complications and long-term results of 334 cases.
Chalouhi, N; Tjoumakaris, S; Gonzalez, L F; Dumont, A S; Starke, R M; Hasan, D; Wu, C; Singhal, S; Moukarzel, L A; Rosenwasser, R; Jabbour, P.
Afiliação
  • Chalouhi N; From the Department of Neurosurgery (N.C., S.T., L.F.G., A.S.D., R.M.S., C.W., S.S., L.A.M., R.R., P.J.), Thomas Jefferson University and Jefferson Hospital for Neuroscience, Philadelphia, Pennsylvania.
AJNR Am J Neuroradiol ; 35(3): 546-52, 2014 Mar.
Article em En | MEDLINE | ID: mdl-23945229
ABSTRACT
BACKGROUND AND

PURPOSE:

Large and giant intracranial aneurysms are increasingly treated with endovascular techniques. The goal of this study was to retrospectively analyze the complications and long-term results of coiling in large and giant aneurysms (≥ 10 mm) and identify predictors of outcome. MATERIALS AND

METHODS:

A total of 334 large or giant aneurysms (≥ 10 mm) were coiled in our institution between 2004 and 2011. Medical charts and imaging studies were reviewed to determine baseline characteristics, procedural complications, and clinical/angiographic outcomes. Aneurysm size was 15 mm on average. Two hundred twenty-five aneurysms were treated with conventional coiling; 88, with stent-assisted coiling; 14, with parent vessel occlusion; and 7, with balloon-assisted coiling.

RESULTS:

Complications occurred in 10.5% of patients, with 1 death (0.3%). Aneurysm location and ruptured aneurysms predicted complications. Angiographic follow-up was available for 84% of patients at 25.4 months on average. Recanalization and retreatment rates were 39% and 33%, respectively. Larger aneurysm size, increasing follow-up time, conventional coiling, and aneurysm location predicted both recurrence and retreatment. The annual rebleeding rate was 1.9%. Larger aneurysm size, increasing follow-up time, and aneurysm location predicted new or recurrent hemorrhage. Favorable outcomes occurred in 92% of patients. Larger aneurysm size, poor Hunt and Hess grades, and new or recurrent hemorrhage predicted poor outcome.

CONCLUSIONS:

Coiling of large and giant aneurysms has a reasonable safety profile with good clinical outcomes, but aneurysm reopening remains very common. Stent-assisted coiling has lower recurrence, retreatment, and new or recurrent hemorrhage rates with no additional morbidity compared with conventional coiling. Aneurysm size was a major determinant of recanalization, retreatment, new or recurrent hemorrhage, and poor outcome.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Aneurisma Intracraniano / Embolização Terapêutica / Procedimentos Endovasculares Tipo de estudo: Diagnostic_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Adolescent / Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: AJNR Am J Neuroradiol Ano de publicação: 2014 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Aneurisma Intracraniano / Embolização Terapêutica / Procedimentos Endovasculares Tipo de estudo: Diagnostic_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Adolescent / Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: AJNR Am J Neuroradiol Ano de publicação: 2014 Tipo de documento: Article