Your browser doesn't support javascript.
loading
Bisacodyl plus split 2-L polyethylene glycol-citrate-simethicone improves quality of bowel preparation before screening colonoscopy.
Valiante, Flavio; Bellumat, Angelo; De Bona, Manuela; De Boni, Michele.
Afiliação
  • Valiante F; Flavio Valiante, Angelo Bellumat, Manuela De Bona, Michele De Boni, Department of Gastroenterology and Digestive Endoscopy, S Maria del Prato Hospital, Feltre, 32032 Belluno, Italy.
World J Gastroenterol ; 19(33): 5493-9, 2013 Sep 07.
Article em En | MEDLINE | ID: mdl-24023492
AIM: To compare the bowel cleansing efficacy, tolerability and acceptability of split 2-L polyethylene glycol (PEG)-citrate-simethicone (PEG-CS) plus bisacodyl (BIS) vs 4-L PEG for fecal occult blood test-positive screening colonoscopy. METHODS: This was a randomised, observer-blind comparative study. Two hundred and sixty-four subjects underwent screening colonoscopy (mean age 62.5 ± 7.4 years, male 61.7%). The primary objective of the study was to compare the bowel cleansing efficacy of the two preparations. INTERVENTIONS: BIS plus PEG-CS: 3 tablets of 5-mg BIS at 16:00, PEG-CS 1-L at 19:00 and 1-L at 7:00, 4-L PEG: 3-L at 17:00, and 1-L at 7:00. Colonoscopy was carried out after 11:00, at least 3 h after the completion of bowel preparation. Bowel cleansing was evaluated using the Harefield Cleansing Scale. RESULTS: Bowel preparation was successful for 92.8% of subjects in the PEG-CS group and for 92.1% of subjects in the 4-L PEG (RR = 1.01; 95%CI: 0.94-1.08). BIS + PEG-CS was better tolerated than 4-L PEG. A greater rate of patients in the BIS + PEG-CS group had no difficulty and/or were willing to repeat the same preparation compared to split-dose 4-L PEG group. Subjects in the BIS + PEG-CS group rated the prep as good or satisfactory in 90.6% as compared to 77% in the 4-L PEG (P = 0.003). Subjects receiving BIS + PEG-CS stated they fully adhered to instructions drinking all the 2-L solution in 97.1% compared with 87.3% in the 4-L PEG (P = 0.003). CONCLUSION: BIS plus split 2-L PEG-CS was as effective as but better tolerated and accepted than split 4-L PEG for screening colonoscopy. This new procedure may increase the positive attitude and participation to colorectal cancer screening colonoscopy.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Polietilenoglicóis / Cloreto de Potássio / Simeticone / Bisacodil / Cloreto de Sódio / Catárticos / Colonoscopia / Ácido Cítrico Tipo de estudo: Clinical_trials / Diagnostic_studies / Screening_studies Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: World J Gastroenterol Assunto da revista: GASTROENTEROLOGIA Ano de publicação: 2013 Tipo de documento: Article País de afiliação: Itália País de publicação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Polietilenoglicóis / Cloreto de Potássio / Simeticone / Bisacodil / Cloreto de Sódio / Catárticos / Colonoscopia / Ácido Cítrico Tipo de estudo: Clinical_trials / Diagnostic_studies / Screening_studies Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: World J Gastroenterol Assunto da revista: GASTROENTEROLOGIA Ano de publicação: 2013 Tipo de documento: Article País de afiliação: Itália País de publicação: Estados Unidos