Colorectal anastomosis facilitated by the use of the LigaSure(®) sealing device: comparative study in an animal model.
Sánchez-De Pedro, Francisco; Moreno-Sanz, Carlos; Morandeira-Rivas, Antonio; Tenías-Burillo, Jose María; Alhambra-Rodríguez De Guzmán, Cristina.
Afiliação
  • Sánchez-De Pedro F; Department of Surgery, «La Mancha Centro¼ General Hospital, Avenida de la Constitución Nº. 3, Alcázar de San Juan, 13600, Ciudad Real, Spain, fsdepedro@gmail.com.
Surg Endosc ; 28(2): 508-14, 2014 Feb.
Article em En | MEDLINE | ID: mdl-24052342
BACKGROUND: Recently, there has been speculation about the possibility of fusing intestinal tissue using bipolar sealing devices. In this study we compare in a porcine model the anastomoses created using the LigaSure(®) device with those created with a stapler after section and closure of a rectal stump. METHODS: Thirty pigs underwent laparoscopic colorectal anastomosis. In group A (n = 15), the division of the intestine and distal stump closure were done with a 10-mm LigaSure Atlas(®) device. In group B, these steps were carried out using an endoscopic stapler. Subsequently, the colorectal anastomosis was performed using circular stapling in both groups. The 4-week follow-up included health status, weight gain, blood tests, X-rays, and colonoscopy. Anastomotic tissue was processed to study the mechanical tensile strength and histopathology. RESULTS: There was no difference in the rate of conversion to open surgery or in average operating time between the groups. In the sealing device group, there was a significantly higher rate of failure in rectal stump closure (p = 0.042). There was one death in group B due to anastomotic leak. There was no difference in adhesion formation or stenosis. Mid-section anastomosis area was 89.7 mm(2) in group A compared with 100 mm(2) in group B (p = 0.52). In tensile strength studies, the maximum load resisted by the sample was 13.8 ± 4.9 N (group A) versus 15.7 ± 4.4 N (group B) (p = 0.17). There was no difference between the groups in degree of reepithelialization, number of inflammatory cells, or the presence of microabscesses. CONCLUSIONS: Division and sealing of the rectal stump with the LigaSure(®) device is feasible in the proposed experimental model, but it is less reliable than conventional closure with a stapler, since it has a significantly greater failure rate. Therefore, The LigaSure(®) device should not be used for this purpose in the clinical setting as this could lead to serious and dramatic complications.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Reto / Técnicas de Sutura / Laparoscopia / Colo Aspecto: Patient_preference Limite: Animals Idioma: En Revista: Surg Endosc Assunto da revista: DIAGNOSTICO POR IMAGEM / GASTROENTEROLOGIA Ano de publicação: 2014 Tipo de documento: Article País de publicação: Alemanha

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Reto / Técnicas de Sutura / Laparoscopia / Colo Aspecto: Patient_preference Limite: Animals Idioma: En Revista: Surg Endosc Assunto da revista: DIAGNOSTICO POR IMAGEM / GASTROENTEROLOGIA Ano de publicação: 2014 Tipo de documento: Article País de publicação: Alemanha