Validation of accumulation models for inorganic suspended solids of different particle size in an activated sludge system.
Bioresour Technol
; 149: 51-7, 2013 Dec.
Article
em En
| MEDLINE
| ID: mdl-24084204
In this study the effect of different particle sizes of inorganic suspended solids (ISS) on the ISS accumulation in an activated sludge system was investigated. The volume mean particle diameters (Dv) of ISS were 26, 73, 106, 165, and 210 µm. There are four fates of ISS in an activated sludge system: (1) suspending in the activated sludge, (2) depositing at the bottom of the reactors, (3) discharged from the reactors via excess sludge, and lastly (4) discharged from the reactors via effluent. The accumulated ISS in the bioreactor was unevenly distributed. Based on the accumulation proportion of ISS in bioreactor, an ISS accumulation model was established, from which the ISS accumulation concentration and the MLVSS/MLSS could be predicted. The proportion of ISS suspending in activated sludge was 0.22, 0.21, 0.042 and 0.031. The proportion of ISS depositing at the bottom of bioreactors was 0.31, 0.47, 0.75, 0.76 and 0.92.
Palavras-chave
Texto completo:
1
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Tamanho da Partícula
/
Esgotos
/
Compostos Inorgânicos
/
Modelos Teóricos
Tipo de estudo:
Prognostic_studies
Idioma:
En
Revista:
Bioresour Technol
Assunto da revista:
ENGENHARIA BIOMEDICA
Ano de publicação:
2013
Tipo de documento:
Article
País de publicação:
Reino Unido