Telesonography: virtual 3D image processing of remotely acquired abdominal, vascular, and fetal sonograms.
Arbeille, Ph; Fornage, B; Boucher, A; Ruiz, J; Georgescu, M; Blouin, J; Cristea, J; Carles, G; Farin, F; Vincent, N.
Afiliação
  • Arbeille P; UMPS-CERCOM University Hospital Trousseau, 37044, Tours, France.
J Clin Ultrasound ; 42(2): 67-73, 2014 Feb.
Article em En | MEDLINE | ID: mdl-24115133
ABSTRACT

PURPOSE:

To design and test a new telesonography technique using remote volume acquisition by untrained operators in locations without access to trained sonographers, postprocessing, and interpretation done at expert centers. MATERIALS AND

METHODS:

The technique was tested with 84 sonograms of organs acquired in pregnant women (n = 8) and patients with various abdominal pathologic conditions (n = 11) located in French Guyana (France), Ceuta (Spain), and Murighiol (Romania). An operator inexperienced in sonography (US) placed the transducer over the predetermined acoustic window for each organ, then swept it from a -45° to a +45° position to scan the targeted organ. The acquired volume dataset was sent to an expert center via the Internet and reconstructed using a proprietary software, which allowed a trained sonographer to navigate through the appropriately reconstructed sonograms.

RESULTS:

After three-dimensional processing at the expert center, the organs scanned in the obstetrical cases were adequately visualized by the expert in seven of eight (88%) examinations of the fetal head, femur, and umbilical cord and eight of eight (100%) examinations of the fetal abdomen and placenta, whereas in the general abdominal cases, the liver, gallbladder, portal vein, and right kidney were correctly visualized in 10 of 11 (91%) examinations.

CONCLUSIONS:

Telesonography allowed untrained operators to scan and transfer the US volume datasets over the Internet to an expert center where an expert sonographer could navigate through the reconstructed US volume and visualize sonograms of diagnostic quality.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Processamento de Imagem Assistida por Computador / Ultrassonografia Pré-Natal / Telemedicina / Imageamento Tridimensional Tipo de estudo: Clinical_trials / Diagnostic_studies Limite: Adult / Female / Humans / Pregnancy Idioma: En Revista: J Clin Ultrasound Ano de publicação: 2014 Tipo de documento: Article País de afiliação: França

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Processamento de Imagem Assistida por Computador / Ultrassonografia Pré-Natal / Telemedicina / Imageamento Tridimensional Tipo de estudo: Clinical_trials / Diagnostic_studies Limite: Adult / Female / Humans / Pregnancy Idioma: En Revista: J Clin Ultrasound Ano de publicação: 2014 Tipo de documento: Article País de afiliação: França