Your browser doesn't support javascript.
loading
Automated image analysis method for detecting and quantifying macrovesicular steatosis in hematoxylin and eosin-stained histology images of human livers.
Nativ, Nir I; Chen, Alvin I; Yarmush, Gabriel; Henry, Scot D; Lefkowitch, Jay H; Klein, Kenneth M; Maguire, Timothy J; Schloss, Rene; Guarrera, James V; Berthiaume, Francois; Yarmush, Martin L.
Afiliação
  • Nativ NI; Department of Biomedical Engineering, Rutgers University, Piscataway, NJ.
Liver Transpl ; 20(2): 228-36, 2014 Feb.
Article em En | MEDLINE | ID: mdl-24339411
Large-droplet macrovesicular steatosis (ld-MaS) in more than 30% of liver graft hepatocytes is a major risk factor for liver transplantation. An accurate assessment of the ld-MaS percentage is crucial for determining liver graft transplantability, which is currently based on pathologists' evaluations of hematoxylin and eosin (H&E)-stained liver histology specimens, with the predominant criteria being the relative size of the lipid droplets (LDs) and their propensity to displace a hepatocyte's nucleus to the cell periphery. Automated image analysis systems aimed at objectively and reproducibly quantifying ld-MaS do not accurately differentiate large LDs from small-droplet macrovesicular steatosis and do not take into account LD-mediated nuclear displacement; this leads to a poor correlation with pathologists' assessments. Here we present an improved image analysis method that incorporates nuclear displacement as a key image feature for segmenting and classifying ld-MaS from H&E-stained liver histology slides. 52,000 LDs in 54 digital images from 9 patients were analyzed, and the performance of the proposed method was compared against the performance of current image analysis methods and the ld-MaS percentage evaluations of 2 trained pathologists from different centers. We show that combining nuclear displacement and LD size information significantly improves the separation between large and small macrovesicular LDs (specificity = 93.7%, sensitivity = 99.3%) and the correlation with pathologists' ld-MaS percentage assessments (linear regression coefficient of determination = 0.97). This performance vastly exceeds that of other automated image analyzers, which typically underestimate or overestimate pathologists' ld-MaS scores. This work demonstrates the potential of automated ld-MaS analysis in monitoring the steatotic state of livers. The image analysis principles demonstrated here may help to standardize ld-MaS scores among centers and ultimately help in the process of determining liver graft transplantability.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Processamento de Imagem Assistida por Computador / Amarelo de Eosina-(YS) / Fígado Gorduroso / Hematoxilina Tipo de estudo: Diagnostic_studies / Etiology_studies / Prognostic_studies / Risk_factors_studies Limite: Humans Idioma: En Revista: Liver Transpl Assunto da revista: GASTROENTEROLOGIA / TRANSPLANTE Ano de publicação: 2014 Tipo de documento: Article País de publicação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Processamento de Imagem Assistida por Computador / Amarelo de Eosina-(YS) / Fígado Gorduroso / Hematoxilina Tipo de estudo: Diagnostic_studies / Etiology_studies / Prognostic_studies / Risk_factors_studies Limite: Humans Idioma: En Revista: Liver Transpl Assunto da revista: GASTROENTEROLOGIA / TRANSPLANTE Ano de publicação: 2014 Tipo de documento: Article País de publicação: Estados Unidos