Your browser doesn't support javascript.
loading
Facile colorimetric method for simple and rapid detection of endotoxin based on counterion-mediated gold nanorods aggregation.
Wang, Yashan; Zhang, Daohong; Liu, Wei; Zhang, Xiao; Yu, Shaoxuan; Liu, Tao; Zhang, Wentao; Zhu, Wenxin; Wang, Jianlong.
Afiliação
  • Wang Y; College of Food Science and Engineering, Northwest A&F University, Yangling 712100, Shaanxi, China.
  • Zhang D; College of Food Science and Engineering, Northwest A&F University, Yangling 712100, Shaanxi, China.
  • Liu W; College of Food Science and Engineering, Northwest A&F University, Yangling 712100, Shaanxi, China.
  • Zhang X; College of Food Science and Engineering, Northwest A&F University, Yangling 712100, Shaanxi, China.
  • Yu S; College of Food Science and Engineering, Northwest A&F University, Yangling 712100, Shaanxi, China.
  • Liu T; College of Food Science and Engineering, Northwest A&F University, Yangling 712100, Shaanxi, China.
  • Zhang W; College of Food Science and Engineering, Northwest A&F University, Yangling 712100, Shaanxi, China.
  • Zhu W; College of Food Science and Engineering, Northwest A&F University, Yangling 712100, Shaanxi, China.
  • Wang J; College of Food Science and Engineering, Northwest A&F University, Yangling 712100, Shaanxi, China. Electronic address: wanglong79@yahoo.com.
Biosens Bioelectron ; 55: 242-8, 2014 May 15.
Article em En | MEDLINE | ID: mdl-24388905
ABSTRACT
Existence of endotoxin in food and injection products indicates bacterial contaminations and therefore poses threat to human health. Herein, a simple and rapid colorimetric method for the effective detection of endotoxin in food and injections based on counterion-mediated gold nanorods aggregation is first proposed. By taking advantage of the color change of unmodified gold nanorods resulted from endotoxin mediated gold nanorods aggregation, endotoxin could be detected in the concentration range of 0.01-0.6 µM. Further, we studied the performance of gold nanorods with different aspect ratios (2.7 and 3.3) in determination of endotoxin and found that gold nanorods with higher aspect ratio (AR) showed superiority in the sensing sensitivity of endotoxin. A good specificity for endotoxin, a detection limit of 0.0084 µM and recoveries ranging from 84% to 109% in spiked food and injection samples are obtained with the colorimetric method. Results demonstrate that the present method provides a novel and effective approach for on-site screening of endotoxin in common products, which is beneficial for monitoring and reducing the risk of bacterial contaminations in food and injections production.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Contaminação de Alimentos / Colorimetria / Nanotubos / Endotoxinas / Análise de Alimentos / Ouro Tipo de estudo: Diagnostic_studies Idioma: En Revista: Biosens Bioelectron Assunto da revista: BIOTECNOLOGIA Ano de publicação: 2014 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Contaminação de Alimentos / Colorimetria / Nanotubos / Endotoxinas / Análise de Alimentos / Ouro Tipo de estudo: Diagnostic_studies Idioma: En Revista: Biosens Bioelectron Assunto da revista: BIOTECNOLOGIA Ano de publicação: 2014 Tipo de documento: Article País de afiliação: China