Computational modelling of long bone fractures fixed with locking plates - How can the risk of implant failure be reduced?
Nassiri, M; Macdonald, B; O'Byrne, J M.
Afiliação
  • Nassiri M; Cappagh National Orthopaedic Hospital, Finglas, Dublin, Ireland.
  • Macdonald B; School of Mechanical Engineering, Dublin City University, Dublin, Ireland.
  • O'Byrne JM; Cappagh National Orthopaedic Hospital, Finglas, Dublin, Ireland.
J Orthop ; 10(1): 29-37, 2013.
Article em En | MEDLINE | ID: mdl-24403745
BACKGROUND AND PURPOSE: The Locking Compression Plate (LCP) is part of a new plate generation requiring an adapted surgical technique and new thinking about commonly used concepts of internal fixation using plates. Knowledge of the fixation stability provided by these new plates is very limited and clarification is still necessary to determine how the mechanical stability and the risk of implant failure can best be controlled. METHODS: Upon validation, a finite element model of an LCP attached to a cylinder was developed to simulate and analyse the biomechanics of a transverse long bone fracture fixed with a locking plate. Of special interest were the factors influencing the mechanical conditions at the fracture site, the control of interfragmentary movement and implant failure. RESULTS: Several factors were shown to influence stability in compression. Increasing translation and/or fracture angle post fixation reduced construct stability. Axial stiffness was also influenced by the working length and plate-bone distance. The fracture gap had no effect on the construct stability when no bone contact occurred during loading. Stress analysis of the LCP demonstrated that the maximum Von Mises stresses were found in the innermost screws at the screw-head junction. INTERPRETATION: For the clinical use of the LCP as a locked internal fixator in fractures with an interfragmentary gap of 1 mm, at least two to four plate holes near the fracture gap should be omitted to allow fracture motion and bone contact to occur. This will also achieve a larger area of stress distribution on the plate and reduce the likelihood of fatigue failure due to cyclic loading.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Etiology_studies / Prognostic_studies / Risk_factors_studies Idioma: En Revista: J Orthop Ano de publicação: 2013 Tipo de documento: Article País de afiliação: Irlanda País de publicação: Índia

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Etiology_studies / Prognostic_studies / Risk_factors_studies Idioma: En Revista: J Orthop Ano de publicação: 2013 Tipo de documento: Article País de afiliação: Irlanda País de publicação: Índia