X-ray ptychographic computed tomography at 16 nm isotropic 3D resolution.
Holler, M; Diaz, A; Guizar-Sicairos, M; Karvinen, P; Färm, Elina; Härkönen, Emma; Ritala, Mikko; Menzel, A; Raabe, J; Bunk, O.
Afiliação
  • Holler M; Paul Scherrer Institut, 5232 Villigen PSI, Switzerland.
  • Diaz A; Paul Scherrer Institut, 5232 Villigen PSI, Switzerland.
  • Guizar-Sicairos M; Paul Scherrer Institut, 5232 Villigen PSI, Switzerland.
  • Karvinen P; Paul Scherrer Institut, 5232 Villigen PSI, Switzerland.
  • Färm E; Department of Chemistry, University of Helsinki, Helsinki, FI-00014, Finland.
  • Härkönen E; Department of Chemistry, University of Helsinki, Helsinki, FI-00014, Finland.
  • Ritala M; Department of Chemistry, University of Helsinki, Helsinki, FI-00014, Finland.
  • Menzel A; Paul Scherrer Institut, 5232 Villigen PSI, Switzerland.
  • Raabe J; Paul Scherrer Institut, 5232 Villigen PSI, Switzerland.
  • Bunk O; Paul Scherrer Institut, 5232 Villigen PSI, Switzerland.
Sci Rep ; 4: 3857, 2014 Jan 24.
Article em En | MEDLINE | ID: mdl-24457289
X-ray ptychography is a scanning variant of coherent diffractive imaging with the ability to image large fields of view at high resolution. It further allows imaging of non-isolated specimens and can produce quantitative mapping of the electron density distribution in 3D when combined with computed tomography. The method does not require imaging lenses, which makes it dose efficient and suitable to multi-keV X-rays, where efficient photon counting, pixelated detectors are available. Here we present the first highly resolved quantitative X-ray ptychographic tomography of an extended object yielding 16 nm isotropic 3D resolution recorded at 2 Šwavelength. This first-of-its-kind demonstration paves the way for ptychographic X-ray tomography to become a promising method for X-ray imaging of representative sample volumes at unmatched resolution, opening tremendous potential for characterizing samples in materials science and biology by filling the resolution gap between electron microscopy and other X-ray imaging techniques.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Sci Rep Ano de publicação: 2014 Tipo de documento: Article País de afiliação: Suíça País de publicação: Reino Unido