Your browser doesn't support javascript.
loading
Comparative Evaluation of Marginal Accuracy of a Cast Fixed Partial Denture Compared to Soldered Fixed Partial Denture Made of Two Different Base Metal Alloys and Casting Techniques: An In vitro Study.
Jei, J Brintha; Mohan, Jayashree.
Afiliação
  • Jei JB; Department of Prosthodontics, SRM Dental College, Ramapuram, Chennai, India ; L62 I Bharathidasan colony, K.K.Nagar, Chennai, 600078 India.
  • Mohan J; Department of Prosthodontics, Vinayaka Mission's Sankarachariar Dental College, Salem, India.
J Indian Prosthodont Soc ; 14(1): 104-9, 2014 Mar.
Article em En | MEDLINE | ID: mdl-24605006
ABSTRACT
The periodontal health of abutment teeth and the durability of fixed partial denture depends on the marginal adaptation of the prosthesis. Any discrepancy in the marginal area leads to dissolution of luting agent and plaque accumulation. This study was done with the aim of evaluating the accuracy of marginal fit of four unit crown and bridge made up of Ni-Cr and Cr-Co alloys under induction and centrifugal casting. They were compared to cast fixed partial denture (FPD) and soldered FPD. For the purpose of this study a metal model was fabricated. A total of 40 samples (4-unit crown and bridge) were prepared in which 20 Cr-Co samples and 20 Ni-Cr samples were fabricated. Within these 20 samples of each group 10 samples were prepared by induction casting technique and other 10 samples with centrifugal casting technique. The cast FPD samples obtained were seated on the model and the samples were then measured with travelling microscope having precision of 0.001 cm. Sectioning of samples was done between the two pontics and measurements were made, then the soldering was made with torch soldering unit. The marginal discrepancy of soldered samples was measured and all findings were statistically analysed. The results revealed minimal marginal discrepancy with Cr-Co samples when compared to Ni-Cr samples done under induction casting technique. When compared to cast FPD samples, the soldered group showed reduced marginal discrepancy.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Prognostic_studies Idioma: En Revista: J Indian Prosthodont Soc Ano de publicação: 2014 Tipo de documento: Article País de publicação: IN / INDIA / ÍNDIA

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Prognostic_studies Idioma: En Revista: J Indian Prosthodont Soc Ano de publicação: 2014 Tipo de documento: Article País de publicação: IN / INDIA / ÍNDIA