Your browser doesn't support javascript.
loading
Spatial correlation of hemodynamic changes related to interictal epileptic discharges with electric and magnetic source imaging.
Heers, Marcel; Hedrich, Tanguy; An, Dongmei; Dubeau, François; Gotman, Jean; Grova, Christophe; Kobayashi, Eliane.
Afiliação
  • Heers M; Montreal Neurological Institute, Department of Neurology and Neurosurgery, McGill University, Montreal, Canada.
Hum Brain Mapp ; 35(9): 4396-414, 2014 Sep.
Article em En | MEDLINE | ID: mdl-24615912
INTRODUCTION: Blood oxygenation level-dependent (BOLD) signal changes at the time of interictal epileptic discharges (IEDs) identify their associated vascular/hemodynamic responses. BOLD activations and deactivations can be found within the epileptogenic zone but also at a distance. Source imaging identifies electric (ESI) and magnetic (MSI) sources of IEDs, with the advantage of a higher temporal resolution. Therefore, the objective of our study was to evaluate the spatial concordance between ESI/MSI and BOLD responses for similar IEDs. METHODS: Twenty-one patients with similar IEDs in simultaneous electroencephalogram/functional magnetic resonance imaging (EEG/fMRI) and in simultaneous EEG/magnetoencephalogram (MEG) recordings were studied. IEDs in EEG/fMRI acquisition were analyzed in an event-related paradigm within a general linear model (GLM). ESI/MSI of averaged IEDs was performed using the Maximum Entropy on the Mean. We assessed the spatial concordance between ESI/MSI and clusters of BOLD activations/deactivations with surface-based metrics. RESULTS: ESI/MSI were concordant with one BOLD cluster for 20/21 patients (concordance with activation: 14/21 patients, deactivation: 6/21 patients, no concordance: 1/21 patients; concordance with MSI only: 3/21, ESI only: 2/21). These BOLD clusters exhibited in 19/20 cases the most significant voxel. BOLD clusters that were spatially concordant with ESI/MSI were concordant with IEDs from invasive recordings in 8/11 patients (activations: 5/8, deactivations: 3/8). CONCLUSION: As the results of BOLD, ESI and MSI are often concordant, they reinforce our confidence in all of them. ESI and MSI confirm the most significant BOLD cluster within BOLD maps, emphasizing the importance of these clusters for the definition of the epileptic focus.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Encéfalo / Imageamento por Ressonância Magnética / Magnetoencefalografia / Circulação Cerebrovascular / Epilepsias Parciais / Eletroencefalografia Tipo de estudo: Observational_studies / Risk_factors_studies Limite: Adult / Humans Idioma: En Revista: Hum Brain Mapp Assunto da revista: CEREBRO Ano de publicação: 2014 Tipo de documento: Article País de afiliação: Canadá País de publicação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Encéfalo / Imageamento por Ressonância Magnética / Magnetoencefalografia / Circulação Cerebrovascular / Epilepsias Parciais / Eletroencefalografia Tipo de estudo: Observational_studies / Risk_factors_studies Limite: Adult / Humans Idioma: En Revista: Hum Brain Mapp Assunto da revista: CEREBRO Ano de publicação: 2014 Tipo de documento: Article País de afiliação: Canadá País de publicação: Estados Unidos