Your browser doesn't support javascript.
loading
Motion correction of multi-contrast images applied to T1and T2quantification in cardiac MRI.
MAGMA ; 28(1): 1-12, 2015 Feb.
Article em En | MEDLINE | ID: mdl-24659257
OBJECT: The ability to manipulate image contrast and thus to obtain complementary information is one of the main advantages of MRI. Motion consistency within the whole data set is a key point in the context of multi contrast imaging. In cardiac and abdominal MRI, the acquisition strategy uses multiple breath-holds and often relies on acceleration methods that inherently suffer from a signal to-noise ratio loss. The aim of this work is to propose a free-breathing multi-contrast acquisition and reconstruction workflow to improve image quality and the subsequent data analysis. MATERIALS AND METHODS: We extended a previously proposed motion-compensated image reconstruction method for multi-contrast imaging. Shared information throughout the imaging protocol is now exploited by the image reconstruction in the form of an additional constraint based on image gradient sparsity. This constraint helps to minimize the amount of data needed for efficient non-rigid motion correction. T1and T2weighted images were reconstructed from free-breathing acquisitions in 4 healthy volunteers and in a phantom. The impact of multi-contrast motion correction was evaluated in a phantom in terms of precision and accuracy of T1and T2quantification. RESULTS: In the phantom, the proposed method achieved an accuracy of 97.5 % on the quantified parameters against 88.0 % before motion correction. In volunteers, motion inconsistency in T1and T2quantification were noticeably reduced within 5 min of free-breathing acquisition. CONCLUSION: An efficient, free-breathing, multi-contrast imaging method has been demonstrated that does not require prior assumptions about contrast and that is applicable to a wide range of examinations.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Algoritmos / Interpretação de Imagem Assistida por Computador / Aumento da Imagem / Artefatos / Imagem Cinética por Ressonância Magnética / Ventrículos do Coração Tipo de estudo: Diagnostic_studies / Evaluation_studies Limite: Humans Idioma: En Revista: MAGMA Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2015 Tipo de documento: Article País de publicação: Alemanha
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Algoritmos / Interpretação de Imagem Assistida por Computador / Aumento da Imagem / Artefatos / Imagem Cinética por Ressonância Magnética / Ventrículos do Coração Tipo de estudo: Diagnostic_studies / Evaluation_studies Limite: Humans Idioma: En Revista: MAGMA Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2015 Tipo de documento: Article País de publicação: Alemanha