Your browser doesn't support javascript.
loading
Long-term sampling of dioxin-like substances from a clinker kiln stack using alternative fuels.
Rivera-Austrui, J; Martinez, K; Marco-Almagro, L; Abalos, M; Abad, E.
Afiliação
  • Rivera-Austrui J; Laboratory of Dioxins, Environmental Chemistry Department, IDAEA-CSIC, J. Girona 18-26, Barcelona 08034, Spain.
  • Martinez K; Laboratory of Dioxins, Environmental Chemistry Department, IDAEA-CSIC, J. Girona 18-26, Barcelona 08034, Spain.
  • Marco-Almagro L; Department of Statistics and Operational Research, Universitat Politècnica de Catalunya, Barcelona, Avda. Diagonal 647, Barcelona 08028, Spain.
  • Abalos M; Laboratory of Dioxins, Environmental Chemistry Department, IDAEA-CSIC, J. Girona 18-26, Barcelona 08034, Spain.
  • Abad E; Laboratory of Dioxins, Environmental Chemistry Department, IDAEA-CSIC, J. Girona 18-26, Barcelona 08034, Spain. Electronic address: esteban.abad@idaea.csic.es.
Sci Total Environ ; 485-486: 528-533, 2014 Jul 01.
Article em En | MEDLINE | ID: mdl-24742561
ABSTRACT
The aim of this work is to characterize atmospheric emissions of polychlorinated dibenzo-p-dioxins (PCDDs)/polychlorinated dibenzofurans (PCDFs) and dioxin-like polychlorinated biphenyls (dl-PCBs) from a cement production plant where the existing clinker production line was completely replaced by a new state-of-the-art installation. The project started in April 2008 with the installation of a long-term sampling system in the stack of the clinker kiln that used petroleum coke as fuel; PCDD/PCDF and dl-PCB emissions were then evaluated for a two year period. To carry out the second part of the study, in 2010 the sampling system was moved to the new installation in which, apart from conventional fuel, recovered derived fuel (RDF) and WWTP sludge were used as alternative fuels. For both the old and new clinker kilns, PCDD/PCDF emission values were well below the limit established by the European Waste Incineration Directive 2000/76/CE (EWID) of 100 pg I-TEQ/Nm(3); values ranged from 0.43 to 2.02 and from 0.07 to 3.31 pg I-TEQ/Nm(3), respectively. dl-PCBs accounted for approximately 25% of the WHO-TEQ toxicity. These results prove that the installation is capable of reducing PCDD/PCDF and dl-PCB emissions when alternative fuels are integrated into the process. In the case of PCDDs/PCDFs, the major contributions to total TEQ were usually from 2,3,7,8-TCDD (owing to its relative abundance) and 2,3,4,7,8-PeCDF (due to its high I-TEF of 0.5); while for dl-PCBs, the major contribution was from PCB-126. The slight shift in the congener profile between the old and new installations was characterized and a regression model was proposed for dl-PCB emissions depending on the RDF flow rate in the clinker.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Coque / Incineração / Poluentes Atmosféricos / Dioxinas Idioma: En Revista: Sci Total Environ Ano de publicação: 2014 Tipo de documento: Article País de afiliação: Espanha

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Coque / Incineração / Poluentes Atmosféricos / Dioxinas Idioma: En Revista: Sci Total Environ Ano de publicação: 2014 Tipo de documento: Article País de afiliação: Espanha