Your browser doesn't support javascript.
loading
A novel high-resolution anorectal manometry parameter based on a three-dimensional integrated pressurized volume of a spatiotemporal plot, for predicting balloon expulsion in asymptomatic normal individuals.
Jung, Kee Wook; Joo, Segyeong; Yang, Dong-Hoon; Yoon, In Ja; Seo, So Young; Kim, Seon-Ok; Lee, Jungbok; Lee, Hyo Jeong; Kim, Kyung Jo; Ye, Byong Duk; Byeon, Jeong-Sik; Jung, Hwoon-Yong; Yang, Suk-Kyun; Kim, Jin-Ho; Myung, Seung-Jae.
Afiliação
  • Jung KW; Department of Gastroenterology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea.
Neurogastroenterol Motil ; 26(7): 937-49, 2014 Jul.
Article em En | MEDLINE | ID: mdl-24758370
ABSTRACT

BACKGROUND:

Anorectal manometry with simulated evacuation (SE) has limited applicability in predicting balloon expulsion (BE) test results. The newly developed high-resolution anorectal manometry (HRAM) technique can yield spatiotemporal plots with three-dimensional pressurization. We aimed to define new parameters based on three-dimensional integrated pressurized volume (IPV) for predicting the BE test results in asymptomatic normal individuals.

METHODS:

Fifty-four asymptomatic healthy individuals were prospectively enrolled. BE tests were performed using 50 mL of water, and a requirement of more than 1 min was considered as delayed BE. HRAM profiles were converted into ASCII files and analyzed using a MATLAB program. A three-dimensional IPV was plotted after transforming the data to a cubic spline interpolation followed by resampling the manometry position at 0.1-cm intervals. KEY

RESULTS:

Eight of the 54 (15%) individuals demonstrated delayed BE. Conventional manometric profiles did not differ significantly between cases of early and delayed BE. Receiver-operator characteristic curve analysis revealed that the ratio of the IPVs of the upper 1 cm to the lower 4 cm of the anorectal canal with balloon distension was more predictable of the BE results (area under curve, 0.73 95% confidence interval, 0.53-0.92; p = 0.04) than the other IPVs or their ratios. CONCLUSIONS & INFERENCES The newly developed IPV methods could predict delayed BE tests during SE better than the conventional parameters defined on the basis of linear waves. Well-designed prospective trials on a large number of subjects are warranted to validate the clinical application of this novel parameter.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Canal Anal / Defecação / Manometria Tipo de estudo: Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Neurogastroenterol Motil Assunto da revista: GASTROENTEROLOGIA / NEUROLOGIA Ano de publicação: 2014 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Canal Anal / Defecação / Manometria Tipo de estudo: Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Neurogastroenterol Motil Assunto da revista: GASTROENTEROLOGIA / NEUROLOGIA Ano de publicação: 2014 Tipo de documento: Article