Your browser doesn't support javascript.
loading
[Periprosthetic and interimplant femoral fractures: Biomechanical analysis]. / Periprothetische und interimplantäre Femurfrakturen : Biomechanische Analyse.
Rupprecht, M; Schlickewei, C; Fensky, F; Morlock, M; Püschel, K; Rueger, J M; Lehmann, W.
Afiliação
  • Rupprecht M; Klinik und Poliklinik für Unfall-, Hand- und Wiederherstellungschirurgie, Universitätsklinik Hamburg-Eppendorf, Martinistr. 52, 20246, Hamburg, Deutschland.
  • Schlickewei C; Abteilung für Kinderorthopädie, Altonaer-Kinderkrankenhaus Hamburg, Hamburg, Deutschland.
  • Fensky F; Klinik und Poliklinik für Unfall-, Hand- und Wiederherstellungschirurgie, Universitätsklinik Hamburg-Eppendorf, Martinistr. 52, 20246, Hamburg, Deutschland.
  • Morlock M; Klinik und Poliklinik für Unfall-, Hand- und Wiederherstellungschirurgie, Universitätsklinik Hamburg-Eppendorf, Martinistr. 52, 20246, Hamburg, Deutschland.
  • Püschel K; Institut für Biomechanik, Technische Universität Hamburg-Harburg, Hamburg-Harburg, Deutschland.
  • Rueger JM; Instituts für Rechtsmedizin, Universitätsklinikum Hamburg-Eppendorf, Hamburg-Eppendorf, Deutschland.
  • Lehmann W; Klinik und Poliklinik für Unfall-, Hand- und Wiederherstellungschirurgie, Universitätsklinik Hamburg-Eppendorf, Martinistr. 52, 20246, Hamburg, Deutschland.
Unfallchirurg ; 118(12): 1025-32, 2015 Dec.
Article em De | MEDLINE | ID: mdl-24893727
ABSTRACT

BACKGROUND:

The requirements for treatment of femoral fractures are increasing with the rising age of the patients. The aim of this study was to evaluate femoral stiffness and the fracture risk after inserting different implants and implant combinations.

METHODS:

A total of 48 cadaveric femors were harvested and 8 groups were randomized on the basis of the bone mineral density (BMD). Different osteosyntheses following prosthetic stem implantation (hip and knee prostheses) were performed and compared with native femurs. All specimens were biomechanically tested in a four-point bending until fracture.

RESULTS:

The insertion of a femoral stem decreases the stiffness by approximately 33%. Ipsilateral retrograde nailing reduces the force to failure even more. This instable situation can be stabilized by a lateral locking compression plate. The most stable situation occurred in the presence of two cemented stems.

CONCLUSION:

Taken together these results clearly indicate that a hip prosthesis significantly weakens the femur, whereas two stems produce the most stable situation at all. The situation of a hip prosthesis and an retrograde nail should be avoided or covered by a bridging-osteosynthesis. In clinical practice an extramedullary fixation technique for distal femoral fractures should be preferred.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Artroplastia de Quadril / Fraturas do Fêmur / Fêmur / Prótese de Quadril Tipo de estudo: Clinical_trials Limite: Aged / Aged80 / Female / Humans / Male Idioma: De Revista: Unfallchirurg Assunto da revista: TRAUMATOLOGIA Ano de publicação: 2015 Tipo de documento: Article País de publicação: ALEMANHA / ALEMANIA / DE / DEUSTCHLAND / GERMANY

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Artroplastia de Quadril / Fraturas do Fêmur / Fêmur / Prótese de Quadril Tipo de estudo: Clinical_trials Limite: Aged / Aged80 / Female / Humans / Male Idioma: De Revista: Unfallchirurg Assunto da revista: TRAUMATOLOGIA Ano de publicação: 2015 Tipo de documento: Article País de publicação: ALEMANHA / ALEMANIA / DE / DEUSTCHLAND / GERMANY