Your browser doesn't support javascript.
loading
Inter-rater reliability of carotid atherosclerotic plaque quantification by 3-dimensional sonography.
Bar, Michal; Roubec, Martin; Farana, Radim; Licev, Lacezar; Tomásková, Hana; Skoloudík, David.
Afiliação
  • Bar M; Department of Neurology and Faculty of Medicine, Faculty Hospital of Ostrava, Ostrava University, Ostrava, Czech Republic (M.B., M.R., D.S.); Faculty of Mechanical Engineering (R.F.) and Electrical Engineering and Computer Science (L.L.), Vysoká Skola Bánská-Technical University of Ostrava, Ostrava,
  • Roubec M; Department of Neurology and Faculty of Medicine, Faculty Hospital of Ostrava, Ostrava University, Ostrava, Czech Republic (M.B., M.R., D.S.); Faculty of Mechanical Engineering (R.F.) and Electrical Engineering and Computer Science (L.L.), Vysoká Skola Bánská-Technical University of Ostrava, Ostrava,
  • Farana R; Department of Neurology and Faculty of Medicine, Faculty Hospital of Ostrava, Ostrava University, Ostrava, Czech Republic (M.B., M.R., D.S.); Faculty of Mechanical Engineering (R.F.) and Electrical Engineering and Computer Science (L.L.), Vysoká Skola Bánská-Technical University of Ostrava, Ostrava,
  • Licev L; Department of Neurology and Faculty of Medicine, Faculty Hospital of Ostrava, Ostrava University, Ostrava, Czech Republic (M.B., M.R., D.S.); Faculty of Mechanical Engineering (R.F.) and Electrical Engineering and Computer Science (L.L.), Vysoká Skola Bánská-Technical University of Ostrava, Ostrava,
  • Tomásková H; Department of Neurology and Faculty of Medicine, Faculty Hospital of Ostrava, Ostrava University, Ostrava, Czech Republic (M.B., M.R., D.S.); Faculty of Mechanical Engineering (R.F.) and Electrical Engineering and Computer Science (L.L.), Vysoká Skola Bánská-Technical University of Ostrava, Ostrava,
  • Skoloudík D; Department of Neurology and Faculty of Medicine, Faculty Hospital of Ostrava, Ostrava University, Ostrava, Czech Republic (M.B., M.R., D.S.); Faculty of Mechanical Engineering (R.F.) and Electrical Engineering and Computer Science (L.L.), Vysoká Skola Bánská-Technical University of Ostrava, Ostrava,
J Ultrasound Med ; 33(7): 1273-8, 2014 Jul.
Article em En | MEDLINE | ID: mdl-24958414
OBJECTIVES: Embolization from atherosclerotic carotid plaques is the most common cause of ischemic stroke; therefore, identification of high-risk plaques by sonography is important. The aim of this study was to investigate the agreement between 2 investigators in the evaluation of sonographic parameters relating to plaque stability. METHODS: The following plaque parameters were assessed: echogenicity, homogeneity, surface, maximum content, and total volume. Serial 2-dimensional (2D) image sequences were obtained. Linear motion of the probe was automatically synchronized with the electrocardiogram. The edges of the plaque in each image were manually identified by the investigators. The total plaque volume was calculated after computer transformation of 2D images into a 3-dimensinoal (3D) format. Inter-rater reliability for echogenicity, homogeneity, and the surface was assessed by the weighted κ coefficient. Parametric values were tested by a paired t test. RESULTS: We enrolled 30 patients (22 male; mean age ± SD, 72 ± 13 years) in the study and evaluated 28 atherosclerotic plaques. Inter-rater agreement values were as follows: homogeneity, 96% (κ = 0.84; P < .001); surface, 90% (κ = 0.77; P < .001); and echogenicity, 86% (κ = 0.60; P < .001). The significance values for plaque content and volume measurement agreement were P = .311 and .312, respectively, and the correlation coefficient was 0.808. CONCLUSIONS: In our study, the agreement between 2 examiners in the evaluation of 2D and 3D sonographic parameters related to plaque stability was good to excellent. The sonographic measurement of plaque volume growth was the most accurate parameter; therefore, 3D sonography may be used for risk assessment of plaques in the future.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Estenose das Carótidas Tipo de estudo: Diagnostic_studies / Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: J Ultrasound Med Ano de publicação: 2014 Tipo de documento: Article País de publicação: Reino Unido

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Estenose das Carótidas Tipo de estudo: Diagnostic_studies / Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: J Ultrasound Med Ano de publicação: 2014 Tipo de documento: Article País de publicação: Reino Unido