Identification of Degradation Products and a Stability-Indicating RP-HPLC Method for the Determination of Flupirtine Maleate in Pharmaceutical Dosage Forms.
Peraman, Ramalingam; Lalitha, K V; Raja, Naga Mallikarjuna; Routhu, Hari Babu.
Afiliação
  • Peraman R; Division of Pharmaceutical Analysis and Quality Assurance, Centre for Pharmaceutical Research (CPR), Raghavendra Institute of Pharmaceutical Education and Research, Anantapuramu, Andhra Pradesh, 515721, India.
  • Lalitha KV; Division of Pharmaceutical Analysis and Quality Assurance, Centre for Pharmaceutical Research (CPR), Raghavendra Institute of Pharmaceutical Education and Research, Anantapuramu, Andhra Pradesh, 515721, India.
  • Raja NM; Division of Pharmaceutical Analysis and Quality Assurance, Centre for Pharmaceutical Research (CPR), Raghavendra Institute of Pharmaceutical Education and Research, Anantapuramu, Andhra Pradesh, 515721, India.
  • Routhu HB; Aurigene Discovery Technologies Limited, Hyderabad, 500049, India.
Sci Pharm ; 82(2): 281-93, 2014.
Article em En | MEDLINE | ID: mdl-24959399
In this stability-indicating, reversed-phase high-performance liquid chromatographic method for flupiritine maleate, forced degradation has been employed and the formed degradants were separated on a C18 column with a 80:20% v/v mixture of methanol-water containing 0.2% (v/v) triethylamine; the pH was adjusted to 3.1. The flow rate was 1 mLmin(-1) and the photodiode array detection wavelength was 254 nm. Forced degradation of the drug was carried out under acidic, basic, thermal, photolytic, peroxide, and neutral conditions. Chromatographic peak purity data indicated no co-eluting peaks with the main peaks. This method resulted in the detection of seven degradation products (D1-D7). Among these, three major degradation products from acidic and basic hydrolysis were identified and characterized by (1)H-NMR, (13)C-NMR, and mass spectral data. The method was validated as per International Conference on Harmonization guidelines (Q2). The linearity of the method was in the concentration range of 20-120 µgmL(-1). The relative standard deviations for intra- and interday precision were below 1.5%. The specificity of the method is suitable for the stability-indicating assay.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Revista: Sci Pharm Ano de publicação: 2014 Tipo de documento: Article País de afiliação: Índia País de publicação: Suíça