Standardization of enterococci density estimates by EPA qPCR methods and comparison of beach action value exceedances in river waters with culture methods.
J Microbiol Methods
; 105: 59-66, 2014 Oct.
Article
em En
| MEDLINE
| ID: mdl-25038459
The U.S. EPA has published recommendations for calibrator cell equivalent (CCE) densities of enterococci in recreational waters determined by a qPCR method in its 2012 recreational water quality criteria (RWQC). The CCE quantification unit stems from the calibration model used to estimate enterococci densities in recreational beach waters in the EPA National Epidemiological and Environmental Assessment of Recreational (NEEAR) Water Study and directly informed the derivation of the RWQC recommendations. Recent studies have demonstrated that CCE estimates from the method can vary when using different cultured Enterococcus cell preparations in calibrator samples. These differences have been attributed to differences in the quantities of targeted gene copies (target sequences) that are recovered per nominal calibrator cell by DNA extraction. Standardization of results from the calibration model will require the estimation of target sequence recoveries from the calibrator and water samples. In addition, comparisons of water sample results with the RWQC values will require a knowledge of target sequence recoveries from the NEEAR study calibrator samples. In this study recoveries of target sequences and the mean target sequence/cell ratio for the NEEAR study calibrator samples were retrospectively estimated with a corroborated standard curve. A modification of the calibration model was then used to estimate enterococci target sequence quantities in water samples from eight midwestern U.S. rivers. CCE estimates were obtained by dividing these target sequence quantities by the mean NEEAR study target sequence/cell ratio. This target sequence-based quantification approach resulted in a high degree of agreement in beach action decisions (determinations of whether bacterial fecal indicator densities are above or below RWQC-recommended values) from CCE results of the qPCR method and from culture dependent enumeration of both enterococci and Eschericia coli in the corresponding water samples.
Palavras-chave
Texto completo:
1
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Praias
/
DNA Bacteriano
/
Enterococcus
/
Rios
/
Carga Bacteriana
/
Reação em Cadeia da Polimerase em Tempo Real
Tipo de estudo:
Evaluation_studies
/
Prognostic_studies
País/Região como assunto:
America do norte
Idioma:
En
Revista:
J Microbiol Methods
Ano de publicação:
2014
Tipo de documento:
Article
País de publicação:
Holanda