Your browser doesn't support javascript.
loading
Automated Competitive Protein-Binding Assay for Total 25-OH Vitamin D, Multicenter Evaluation and Practical Performance.
Wielders, Jos P M; Carter, Graeme F; Eberl, Heike; Morris, Gary; Roth, Heinz Jürgen; Vogl, Christian.
Afiliação
  • Wielders JP; Meander Medisch Centrum, Amersfoort, The Netherlands.
  • Carter GF; Healthscope Pathology, Clayton, Victoria, Australia.
  • Eberl H; Roche Diagnostics GmbH, Penzberg, Germany.
  • Morris G; Southern IML Pathology, Wollongong, New South Wales, Australia.
  • Roth HJ; Limbach Laboratories, Heidelberg, Germany.
  • Vogl C; Roche Diagnostics GmbH, Penzberg, Germany.
J Clin Lab Anal ; 29(6): 451-61, 2015 Nov.
Article em En | MEDLINE | ID: mdl-25132191
BACKGROUND: The Roche Elecsys Vitamin D Total competitive protein-binding assay uses recombinant vitamin D binding protein for measuring 25-hydroxyvitamin D (25-OHD), which is different from commonly used antibody assays. METHODS: The assay, standardized against LC-MS/MS, was tested at four sites. Evaluation included precision; between-laboratory variability; functional sensitivity; correlation to LC-MS/MS, HPLC, and immunoassays; as well as robustness, traceability, and EQAS performance. RESULTS: Precision testing showed within-run coefficient of variations (CVs) of ≤ 7%, within-laboratory CVs of <9.5%, between-laboratory precision CVs of ≤ 10.1%, and a functional sensitivity below 9.8 nmol/l (at CV 12.9%). The assay showed equivalent 25-OHD levels for matched serum and plasma samples, good reagent lot-to-lot consistency in pooled sera over time, and good agreement with HPLC (relative bias -8.8%). Comparison with LC-MS/MS methods yielded relative biases of -15.4, -13.5, -10.2, and 3.2%. Comparison against immunoassays showed a relative bias of 14.5% (DiaSorin Liaison) and -58.2% (IDS-iSYS). The overall mean results in 2 years DEQAS was 102% of the ALTM. In a certified reference patient panel, the average bias was < 4% for the sum of 25-OHD2 and 25-OHD3. CONCLUSION: The Elecsys Vitamin D Total assay demonstrated good overall performance and is, according to present standards, very suitable for automated measurement of 25-OHD.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Proteína de Ligação a Vitamina D / Análise Química do Sangue / 25-Hidroxivitamina D 2 / Testes Diagnósticos de Rotina Tipo de estudo: Clinical_trials / Evaluation_studies Limite: Humans Idioma: En Revista: J Clin Lab Anal Assunto da revista: TECNICAS E PROCEDIMENTOS DE LABORATORIO Ano de publicação: 2015 Tipo de documento: Article País de afiliação: Holanda País de publicação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Proteína de Ligação a Vitamina D / Análise Química do Sangue / 25-Hidroxivitamina D 2 / Testes Diagnósticos de Rotina Tipo de estudo: Clinical_trials / Evaluation_studies Limite: Humans Idioma: En Revista: J Clin Lab Anal Assunto da revista: TECNICAS E PROCEDIMENTOS DE LABORATORIO Ano de publicação: 2015 Tipo de documento: Article País de afiliação: Holanda País de publicação: Estados Unidos