Your browser doesn't support javascript.
loading
Design and construction of a thermal neutron beam for BNCT at Tehran Research Reactor.
Kasesaz, Yaser; Khalafi, Hossein; Rahmani, Faezeh; Ezzati, Arsalan; Keyvani, Mehdi; Hossnirokh, Ashkan; Shamami, Mehrdad Azizi; Amini, Sepideh.
Afiliação
  • Kasesaz Y; Nuclear Science and Technology Research Institute (NSTRI), Iran.
  • Khalafi H; Nuclear Science and Technology Research Institute (NSTRI), Iran. Electronic address: Hossein_khalafi@yahoo.com.
  • Rahmani F; Department of Physics, K. N. Toosi University of Technology, Iran.
  • Ezzati A; Nuclear Science and Technology Research Institute (NSTRI), Iran.
  • Keyvani M; Nuclear Science and Technology Research Institute (NSTRI), Iran.
  • Hossnirokh A; Nuclear Science and Technology Research Institute (NSTRI), Iran.
  • Shamami MA; Nuclear Science and Technology Research Institute (NSTRI), Iran.
  • Amini S; Nuclear Science and Technology Research Institute (NSTRI), Iran.
Appl Radiat Isot ; 94: 149-151, 2014 Dec.
Article em En | MEDLINE | ID: mdl-25195172
ABSTRACT
An irradiation facility has been designed and constructed at Tehran Research Reactor (TRR) for the treatment of shallow tumors using Boron Neutron Capture Therapy (BNCT). TRR has a thermal column which is about 3m in length with a wide square cross section of 1.2×1.2m(2). This facility is filled with removable graphite blocks. The aim of this work is to perform the necessary modifications in the thermal column structure to meet thermal BNCT beam criteria recommended by International Atomic Energy Agency. The main modifications consist of rearranging graphite blocks and reducing the gamma dose rate at the beam exit. Activation foils and TLD700 dosimeter have been used to measure in-air characteristics of the neutron beam. According to the measurements, a thermal flux is 5.6×10(8) (ncm(-2)s(-1)), a cadmium ratio is 186 for gold foils and a gamma dose rate is 0.57Gy h(-1).
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Proteção Radiológica / Radiometria / Terapia por Captura de Nêutron de Boro / Nêutrons / Reatores Nucleares Tipo de estudo: Evaluation_studies País/Região como assunto: Asia Idioma: En Revista: Appl Radiat Isot Assunto da revista: MEDICINA NUCLEAR / SAUDE AMBIENTAL Ano de publicação: 2014 Tipo de documento: Article País de afiliação: Irã

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Proteção Radiológica / Radiometria / Terapia por Captura de Nêutron de Boro / Nêutrons / Reatores Nucleares Tipo de estudo: Evaluation_studies País/Região como assunto: Asia Idioma: En Revista: Appl Radiat Isot Assunto da revista: MEDICINA NUCLEAR / SAUDE AMBIENTAL Ano de publicação: 2014 Tipo de documento: Article País de afiliação: Irã