Your browser doesn't support javascript.
loading
High protracted (99m)Tc-HDP uptake in synthetic bone implants - a potentially misleading incidental finding on bone scintigraphy.
Tabouret-Viaud, Claire; Mainta, Ismini; Boudabbous, Sana; Amzalag, Gaël; Ratib, Osman; Rager, Olivier; Paycha, Frédéric.
Afiliação
  • Tabouret-Viaud C; Service de Médecine Nucléaire, Hôpitaux Universitaires de Genève, rue Gabrielle-Perret-Gentil, 4, CH-1211 Genève, Switzerland. Electronic address: Claire.TabouretViaud@hcuge.ch.
  • Mainta I; Service de Médecine Nucléaire, Hôpitaux Universitaires de Genève, rue Gabrielle-Perret-Gentil, 4, CH-1211 Genève, Switzerland.
  • Boudabbous S; Service de Radiologie, Hôpitaux Universitaires de Genève, rue Gabrielle-Perret-Gentil, 4, CH-1211 Genève, Switzerland.
  • Amzalag G; Service de Médecine Nucléaire, Hôpitaux Universitaires de Genève, rue Gabrielle-Perret-Gentil, 4, CH-1211 Genève, Switzerland.
  • Ratib O; Service de Médecine Nucléaire, Hôpitaux Universitaires de Genève, rue Gabrielle-Perret-Gentil, 4, CH-1211 Genève, Switzerland.
  • Rager O; Service de Médecine Nucléaire, Hôpitaux Universitaires de Genève, rue Gabrielle-Perret-Gentil, 4, CH-1211 Genève, Switzerland.
  • Paycha F; Service de Médecine Nucléaire, Hôpital Lariboisière, 2 rue Ambroise Paré, 75010 Paris, France.
Knee ; 21(6): 1284-7, 2014 Dec.
Article em En | MEDLINE | ID: mdl-25224667
ABSTRACT
We report the case of a 56-year-old male with bilateral total knee prostheses suffering from bilateral knee pain mainly on the right side and referred for bone scintigraphy. The medical history of the patient revealed an opening wedge high tibial osteotomy performed nine years earlier, with insertion of two blocks of ceramic made of hydroxyapatite and tricalcium phosphate in a wedge configuration as synthetic bone substitutes. The porous structure of these implants is analogous to the architecture of cancellous bone and permits fibrovascular and bone ingrowth, promoting the healing process. Planar scintigraphy and SPECT/CT showed an intense uptake within those implants in the early phase as well as in the late phase of the bone scan. It also showed bilateral patellofemoral arthritis. A (99m)Tc-labeled antigranulocyte antibody scintigraphy was negative for infection or inflammation. Bilateral patellar resurfacing led to complete symptom regression, confirmed at 10 months follow-up. To the best of our knowledge, this scintigraphic pattern with such a high tracer uptake reflecting bone substitute osteointegration has not yet been published. This should be considered in patients with such bone replacement materials that are increasingly used, in order to avoid false diagnosis of inflammation or infection.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Osteomielite / Medronato de Tecnécio Tc 99m / Compostos Radiofarmacêuticos / Artroplastia do Joelho / Síndrome da Dor Patelofemoral / Articulação do Joelho / Prótese do Joelho Tipo de estudo: Diagnostic_studies / Etiology_studies Limite: Humans / Male / Middle aged Idioma: En Revista: Knee Assunto da revista: ORTOPEDIA Ano de publicação: 2014 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Osteomielite / Medronato de Tecnécio Tc 99m / Compostos Radiofarmacêuticos / Artroplastia do Joelho / Síndrome da Dor Patelofemoral / Articulação do Joelho / Prótese do Joelho Tipo de estudo: Diagnostic_studies / Etiology_studies Limite: Humans / Male / Middle aged Idioma: En Revista: Knee Assunto da revista: ORTOPEDIA Ano de publicação: 2014 Tipo de documento: Article