ABSTRACT

PURPOSE:

To develop a model for the Cirrus HD-OCT that allows for the comparison of retinal nerve fiber layer (RNFL) thickness measurements with dissimilar signal strengths (SS) and accounts for test-retest variability.

METHODS:

Retinal nerve fiber layers were obtained in normals using the Cirrus optic disc cube 200 × 200 protocol during a single encounter. Five RNFL scans were obtained with a SS of 9 or 10. Diffusion lens filters were used to degrade SS to obtain five scans at each SS group of 7 or 8, 5 or 6, and 3 or 4. The relationship between average RNFL thickness and SS was established, and an equation was developed to allow for adjustment of an RNFL measurement had it been a SS of 7. Intravisit interclass correlation coefficient (ICC) and coefficient of variation (CV) parameter estimates for each SS group were calculated. Repeatability and upper tolerance limit were calculated as 1.96 × âˆš2 × within-subject standard deviation (Sw) and 1.645 × âˆš2 × Sw, respectively.

RESULTS:

There was a linear relationship between average RNFL and SS. RNFLadj = RNFL - 1.03*SS + 7.21 allows for the adjustment of RNFL readings to the same SS. Interclass correlation coefficients and CVs were good for all measurements down to SS of 3 or 4. Repeatability and upper tolerance limit were 5.24 and 4.40 µm, respectively.

CONCLUSIONS:

Our model adjusts RNFL readings based on SS and includes an upper tolerance limit of 5 µm. If validated, this model could improve the detection of real RNFL changes. Further study to validate this model should be performed before widespread use is adopted.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Disco Óptico / Células Ganglionares da Retina / Algoritmos / Doenças do Nervo Óptico / Tomografia de Coerência Óptica / Modelos Teóricos / Fibras Nervosas Tipo de estudo: Clinical_trials / Prognostic_studies Limite: Humans Idioma: En Revista: Invest Ophthalmol Vis Sci Ano de publicação: 2014 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Disco Óptico / Células Ganglionares da Retina / Algoritmos / Doenças do Nervo Óptico / Tomografia de Coerência Óptica / Modelos Teóricos / Fibras Nervosas Tipo de estudo: Clinical_trials / Prognostic_studies Limite: Humans Idioma: En Revista: Invest Ophthalmol Vis Sci Ano de publicação: 2014 Tipo de documento: Article País de afiliação: Estados Unidos