Your browser doesn't support javascript.
loading
Faraday-effect polarimeter-interferometer system for current density measurement on EAST.
Liu, H Q; Jie, Y X; Ding, W X; Brower, D L; Zou, Z Y; Li, W M; Wang, Z X; Qian, J P; Yang, Y; Zeng, L; Lan, T; Wei, X C; Li, G S; Hu, L Q; Wan, B N.
Afiliação
  • Liu HQ; Institute of Plasma Physics, Chinese Academy of Sciences, Hefei, Anhui 230031, People's Republic of China.
  • Jie YX; Institute of Plasma Physics, Chinese Academy of Sciences, Hefei, Anhui 230031, People's Republic of China.
  • Ding WX; Department of Physics and Astronomy, University of California Los Angeles, Los Angeles, California 90095, USA.
  • Brower DL; Department of Physics and Astronomy, University of California Los Angeles, Los Angeles, California 90095, USA.
  • Zou ZY; Institute of Plasma Physics, Chinese Academy of Sciences, Hefei, Anhui 230031, People's Republic of China.
  • Li WM; Institute of Plasma Physics, Chinese Academy of Sciences, Hefei, Anhui 230031, People's Republic of China.
  • Wang ZX; Institute of Plasma Physics, Chinese Academy of Sciences, Hefei, Anhui 230031, People's Republic of China.
  • Qian JP; Institute of Plasma Physics, Chinese Academy of Sciences, Hefei, Anhui 230031, People's Republic of China.
  • Yang Y; Institute of Plasma Physics, Chinese Academy of Sciences, Hefei, Anhui 230031, People's Republic of China.
  • Zeng L; Institute of Plasma Physics, Chinese Academy of Sciences, Hefei, Anhui 230031, People's Republic of China.
  • Lan T; Institute of Plasma Physics, Chinese Academy of Sciences, Hefei, Anhui 230031, People's Republic of China.
  • Wei XC; Institute of Plasma Physics, Chinese Academy of Sciences, Hefei, Anhui 230031, People's Republic of China.
  • Li GS; Institute of Plasma Physics, Chinese Academy of Sciences, Hefei, Anhui 230031, People's Republic of China.
  • Hu LQ; Institute of Plasma Physics, Chinese Academy of Sciences, Hefei, Anhui 230031, People's Republic of China.
  • Wan BN; Institute of Plasma Physics, Chinese Academy of Sciences, Hefei, Anhui 230031, People's Republic of China.
Rev Sci Instrum ; 85(11): 11D405, 2014 Nov.
Article em En | MEDLINE | ID: mdl-25430168
ABSTRACT
A multichannel far-infrared laser-based POlarimeter-INTerferometer (POINT) system utilizing the three-wave technique is under development for current density and electron density profile measurements in the EAST tokamak. Novel molybdenum retro-reflectors are mounted in the inside wall for the double-pass optical arrangement. A Digital Phase Detector with 250 kHz bandwidth, which will provide real-time Faraday rotation angle and density phase shift output, have been developed for use on the POINT system. Initial calibration indicates the electron line-integrated density resolution is less than 5 × 10(16) m(-2) (∼2°), and the Faraday rotation angle rms phase noise is <0.1°.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Rev Sci Instrum Ano de publicação: 2014 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Rev Sci Instrum Ano de publicação: 2014 Tipo de documento: Article