Your browser doesn't support javascript.
loading
Monte-Carlo simulation of noise in hard X-ray Transmission Crystal Spectrometers: identification of contributors to the background noise and shielding optimization.
Thfoin, I; Reverdin, C; Hulin, S; Szabo, C I; Bastiani-Ceccotti, S; Batani, D; Brambrink, E; Koenig, M; Duval, A; Leboeuf, X; Lecherbourg, L; Rossé, B; Morace, A; Santos, J J; Vaisseau, X; Fourment, C; Giuffrida, L; Nakatsutsumi, M.
Afiliação
  • Thfoin I; CEA, DAM, DIF, F-91297 Arpajon, France.
  • Reverdin C; CEA, Centre de Saclay, IRFU, F-91191 Gif-sur-Yvette, France.
  • Hulin S; CELIA, Université de Bordeaux-CNRS-CEA, F-33405 Talence, France.
  • Szabo CI; Laboratoire Kastler Brossel, ENS, CNRS, UPMC, 75005 Paris Cedex, France.
  • Bastiani-Ceccotti S; LULI Ecole Polytechnique, CNRS, CEA, UPMC, 91128 Palaiseau, France.
  • Batani D; CELIA, Université de Bordeaux-CNRS-CEA, F-33405 Talence, France.
  • Brambrink E; LULI Ecole Polytechnique, CNRS, CEA, UPMC, 91128 Palaiseau, France.
  • Koenig M; LULI Ecole Polytechnique, CNRS, CEA, UPMC, 91128 Palaiseau, France.
  • Duval A; CEA, Centre de Saclay, IRFU, F-91191 Gif-sur-Yvette, France.
  • Leboeuf X; CEA, Centre de Saclay, IRFU, F-91191 Gif-sur-Yvette, France.
  • Lecherbourg L; CEA, Centre de Saclay, IRFU, F-91191 Gif-sur-Yvette, France.
  • Rossé B; CEA, Centre de Saclay, IRFU, F-91191 Gif-sur-Yvette, France.
  • Morace A; University of Milano, via Celoria 16, 20133 Milano, Italy.
  • Santos JJ; CELIA, Université de Bordeaux-CNRS-CEA, F-33405 Talence, France.
  • Vaisseau X; CELIA, Université de Bordeaux-CNRS-CEA, F-33405 Talence, France.
  • Fourment C; CELIA, Université de Bordeaux-CNRS-CEA, F-33405 Talence, France.
  • Giuffrida L; CELIA, Université de Bordeaux-CNRS-CEA, F-33405 Talence, France.
  • Nakatsutsumi M; LULI Ecole Polytechnique, CNRS, CEA, UPMC, 91128 Palaiseau, France.
Rev Sci Instrum ; 85(11): 11D615, 2014 Nov.
Article em En | MEDLINE | ID: mdl-25430191
ABSTRACT
Transmission crystal spectrometers (TCS) are used on many laser facilities to record hard X-ray spectra. During experiments, signal recorded on imaging plates is often degraded by a background noise. Monte-Carlo simulations made with the code GEANT4 show that this background noise is mainly generated by diffusion of MeV electrons and very hard X-rays. An experiment, carried out at LULI2000, confirmed that the use of magnets in front of the diagnostic, that bent the electron trajectories, reduces significantly this background. The new spectrometer SPECTIX (Spectromètre PETAL à Cristal en TransmIssion X), built for the LMJ/PETAL facility, will include this optimized shielding.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Revista: Rev Sci Instrum Ano de publicação: 2014 Tipo de documento: Article País de afiliação: França

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Revista: Rev Sci Instrum Ano de publicação: 2014 Tipo de documento: Article País de afiliação: França