Your browser doesn't support javascript.
loading
A Comparasion in Graft Resorption between Three Techniques of Diced Cartilage Using Surgical Blade, Electrical Grinder and Grater in Rabbit.
Manafi, Ali; Sabet, Mohammad; Emami, Abolhasan; Vasei, Mohammad; Mosavi, Jaber; Manafi, Amir; Hamedi, Zahra Sadat; Manafi, Farzad; Mehrabani, Golnoush; Manafi, Navid.
Afiliação
  • Manafi A; Department of Plastic Surgery, Tehran University of Medical Sciences, Tehran, Iran;
  • Sabet M; Department of Plastic Surgery, Tehran University of Medical Sciences, Tehran, Iran;
  • Emami A; Department of Plastic Surgery, Tehran University of Medical Sciences, Tehran, Iran;
  • Vasei M; Department of Pathology, Tehran University of Medical Sciences, Teharn, Iran;
  • Mosavi J; Department of Plastic Surgery, Tehran University of Medical Sciences, Tehran, Iran;
  • Manafi A; Student Research Committee, Shahid Beheshti University of Medical Sciences, Teharn, Iran;
  • Hamedi ZS; Student Research Committee, Shahid Beheshti University of Medical Sciences, Teharn, Iran;
  • Manafi F; Student Research Committee, Iran University of Medical Sciences, Teharn, Iran;
  • Mehrabani G; Student Research Committee, Shiraz University of Medical Sciences, Shiraz, Iran;
  • Manafi N; Student Research Committee, Zanjan University of Medical Sciences, Zanjan, Iran.
World J Plast Surg ; 3(1): 52-63, 2014 Jan.
Article em En | MEDLINE | ID: mdl-25489525
ABSTRACT

BACKGROUND:

In recent years, there is an increasing tendency to use diced cartilage grafts in rhinoplasty surgery for improving dorsum contour irregularities. This study was designed to compare graft resorption between three techniques of diced cartilage using surgical blade, electrical grinder and grater in rabbit model.

METHODS:

Thirteen New Zealand rabbits were divided into three groups. Three 2×2 cm cartilage specimens were harvested from one of their ears. In group one, the cartilage was diced by use of No11 surgical blade to o.5 to 1 mm cube pieces. In group two, an electrical grinder was used and in group three, a grater was applied. The grafts were placed in three subcutaneous pockets in the back of rabbits and after 12 weeks, the implants were removed and their weight and volume were recorded and were evaluated by histological techniques.

RESULTS:

There was no difference between the three methods in the 3 groups for graft resorption. There was no change in the volume, but the weight showed a decrease in the control group.

CONCLUSIONS:

As the histological results had no statistically difference between groups, we may recommend use of these two techniques in reconstructive and in aesthetic cases.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: World J Plast Surg Ano de publicação: 2014 Tipo de documento: Article