Effect of anatomic, semi-anatomic and non-anatomic occlusal surface tooth preparations on the adaptation of zirconia copings.
Habib, Syed Rashid; Asiri, Waleed; Hefne, Mohammed Jameel.
Afiliação
  • Habib SR; Department of Prosthetic Dental Sciences, College of Dentistry, King Saud University, Riyadh, Kingdom of Saudi Arabia.
  • Asiri W; College of Dentistry, King Saud University, Riyadh, Kingdom of Saudi Arabia.
  • Hefne MJ; College of Dentistry, King Saud University, Riyadh, Kingdom of Saudi Arabia.
J Adv Prosthodont ; 6(6): 444-50, 2014 Dec.
Article em En | MEDLINE | ID: mdl-25551003
PURPOSE: To compare the accuracy of marginal and internal adaptation of zirconia (Zr) copings fabricated on anatomic (A), semi-anatomic (SA) and non-anatomic (NA) occlusal surface preparations. MATERIALS AND METHODS: 45 extracted bicuspid teeth were prepared for receiving zirconia crowns, with different occlusal preparation designs A=15, SA=15 & NA=15. The Zr copings were fabricated by using CAD4DENT, CAD/CAM. The copings were adjusted, cemented and were cross sectioned centrally from buccal cusp tip to lingual cusp tip into mesial and distal halves. The copings were examined under electron microscope at ×200 magnification and the measurements were recorded at 9 predetermined areas in micrometers. RESULTS: Overall mean gap values for the three groups was found to be 155.93±33.98 µm with Anatomical Occlusal preparation design having the least gap value of 139.23±30.85 µm showing the best adaptation among the groups. Post Hoc Tukey's test showed a statistically significant difference (P=.007) between the means of gap for A & NA preparation designs. Measurements recorded at 9 predetermined points showed variations for the three groups. CONCLUSION: Anatomical occlusal preparation designs resulted in better marginal and internal adaptation of Zr copings. There is a considerable variation between the measured marginal and internal gap values for the Zr copings fabricated by the (CAD4DENT-CAD/CAM). This variation may be associated with the lack of standardization of the preparation of teeth, computerized designing of the coping for each tooth, cement used, uniform pressure application during the cementation of the copings, sectioning of the copings and the microscopic measurements.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: J Adv Prosthodont Ano de publicação: 2014 Tipo de documento: Article País de publicação: Coréia do Sul

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: J Adv Prosthodont Ano de publicação: 2014 Tipo de documento: Article País de publicação: Coréia do Sul