Reflective multilayer optic as hard X-ray diagnostic on laser-plasma experiment.
Brejnholt, N F; Decker, T A; Hill, R M; Chen, H; Williams, G J; Park, J; Alameda, J B; Fernández-Perea, M; Pivovaroff, M J; Soufli, R; Descalle, M-A; Peebles, J; Kerr, S M.
Afiliação
  • Brejnholt NF; Lawrence Livermore National Laboratory, Livermore, California 94550, USA.
  • Decker TA; Lawrence Livermore National Laboratory, Livermore, California 94550, USA.
  • Hill RM; Lawrence Livermore National Laboratory, Livermore, California 94550, USA.
  • Chen H; Lawrence Livermore National Laboratory, Livermore, California 94550, USA.
  • Williams GJ; Lawrence Livermore National Laboratory, Livermore, California 94550, USA.
  • Park J; Lawrence Livermore National Laboratory, Livermore, California 94550, USA.
  • Alameda JB; Lawrence Livermore National Laboratory, Livermore, California 94550, USA.
  • Fernández-Perea M; Lawrence Livermore National Laboratory, Livermore, California 94550, USA.
  • Pivovaroff MJ; Lawrence Livermore National Laboratory, Livermore, California 94550, USA.
  • Soufli R; Lawrence Livermore National Laboratory, Livermore, California 94550, USA.
  • Descalle MA; Lawrence Livermore National Laboratory, Livermore, California 94550, USA.
  • Peebles J; Jacobs School of Engineering, UC San Diego, La Jolla, California 92093, USA.
  • Kerr SM; University of Alberta, Edmonton, Alberta T6G 2R3, Canada.
Rev Sci Instrum ; 86(1): 013110, 2015 Jan.
Article em En | MEDLINE | ID: mdl-25638075
A multilayer-based optic was tested for use as an X-ray diagnostic on a laser-plasma experiment. The multilayer optic was employed to selectively pass X-rays between 55 and 100 keV. An order of magnitude improvement in signal-to-noise ratio is achieved compared to a transmission crystal spectrometer. A multilayer response model, taking into account the source size and spectral content, is constructed and the outlook for application above 500 keV is briefly discussed. LLNL-JRNL-664311.