Your browser doesn't support javascript.
loading
Determination of seven selected neuro- and immunomodulatory steroids in human cerebrospinal fluid and plasma using LC-MS/MS.
Sosvorova, Lucie; Vitku, Jana; Chlupacova, Tereza; Mohapl, Milan; Hampl, Richard.
Afiliação
  • Sosvorova L; Institute of Endocrinology, Department of Steroids and Proteofactors, Narodni 8, 11694 Prague, Czech Republic.
  • Vitku J; Institute of Endocrinology, Department of Steroids and Proteofactors, Narodni 8, 11694 Prague, Czech Republic.
  • Chlupacova T; Institute of Endocrinology, Department of Steroids and Proteofactors, Narodni 8, 11694 Prague, Czech Republic.
  • Mohapl M; Military University Hospital Prague, Department of Neurosurgery, U Vojenske nemocnice 1200, 16902 Prague, Czech Republic.
  • Hampl R; Institute of Endocrinology, Department of Steroids and Proteofactors, Narodni 8, 11694 Prague, Czech Republic. Electronic address: rhampl@endo.cz.
Steroids ; 98: 1-8, 2015 Jun.
Article em En | MEDLINE | ID: mdl-25676787
Dehydroepiandrosterone (DHEA) and its 7-oxo- and 7-hydroxy-metabolites occurring in the brain are considered neurosteroids. Metabolism of the latter is catalysed by 11ß-hydroxysteroid dehydrogenase (11ß-HSD) which also interconverts cortisol and cortisone. The concurrent metabolic reaction to DHEA 7-hydroxylation is the formation of 16α-hydroxy-DHEA. The LC-MS/MS method using triple stage quadrupole-mass spectrometer was developed for simultaneous quantification of free DHEA, 7α-hydroxy-DHEA, 7ß-hydroxy-DHEA, 7-oxo-DHEA, 16α-hydroxy-DHEA, cortisol and cortisone in human plasma and cerebrospinal fluid (CSF). The method employs 500 µL of human plasma and 3000 µL of CSF extracted with diethyl ether and derivatized with 2-hydrazinopyridine. It has been validated in terms of sensitivity, precision and recovery. In plasma, the following values were obtained: limit of detection: 2-50p g/mL; limit of quantification: 5-140 pg/mL; within-day precision 0.58-14.58%; between-day precision: 1.24-13.89% and recovery: 85-113.2%). For CSF, the values of limit of detection: 2-28 pg/mL; limit of quantification: 6-94 pg/mL; within-day precision; 0.63-5.48%; between-day precision: 0.88-14.59% and recovery: 85.1-109.4% were acquired. Medians and concentration ranges of detected steroids in plasma and CSF are given in subjects with excluded normal pressure hydrocephalus (n=37; 65-80 years). The method enables simultaneous quantification of steroids important for the estimation of 11ß-HSD activity in human plasma and CSF. It will be helpful in better understanding various degenerative diseases development and progression.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Desidroepiandrosterona / Neurotransmissores / Fatores Imunológicos Limite: Aged / Aged80 / Female / Humans / Male Idioma: En Revista: Steroids Ano de publicação: 2015 Tipo de documento: Article País de afiliação: República Tcheca País de publicação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Desidroepiandrosterona / Neurotransmissores / Fatores Imunológicos Limite: Aged / Aged80 / Female / Humans / Male Idioma: En Revista: Steroids Ano de publicação: 2015 Tipo de documento: Article País de afiliação: República Tcheca País de publicação: Estados Unidos