Your browser doesn't support javascript.
loading
Ultrasensitive electrochemical detection of secretoneurin based on Pb(2+)-decorated reduced graphene oxide-tetraethylene pentamine as a label.
Yuan, Guolin; Chen, Huali; Xia, Chunyong; Gao, Liuliu; Yu, Chao.
Afiliação
  • Yuan G; Institute of Life Science and School of Public Health, Chongqing Medical University, Chongqing 400016, PR China.
  • Chen H; Institute of Life Science and School of Public Health, Chongqing Medical University, Chongqing 400016, PR China.
  • Xia C; Institute of Life Science and School of Public Health, Chongqing Medical University, Chongqing 400016, PR China.
  • Gao L; Institute of Life Science and School of Public Health, Chongqing Medical University, Chongqing 400016, PR China.
  • Yu C; Institute of Life Science and School of Public Health, Chongqing Medical University, Chongqing 400016, PR China. Electronic address: yuchaom@163.com.
Biosens Bioelectron ; 69: 95-9, 2015 Jul 15.
Article em En | MEDLINE | ID: mdl-25706062
ABSTRACT
In this work, a novel electrochemical immunosensor for the detection of secretoneurin (SN), which uses metal ion functionalised reduced graphene oxide-tetraethylene pentamine (rGO-TEPA) as a label, is reported for the first time. rGO-TEPA contains a large number of amino groups, which makes it an ideal templet for the loading of metal ions. rGO-TEPA-Pb(2+) was employed to immobilise secondary secretoneurin (SN) antibody (Ab2), and the resulting nanocomposite (Ab2-rGO-TEPA-Pb(2+)) was used as a trace tag for signal amplification. A modified electrode consisting of functionalised graphene nanosheets (Au@GS) was used as a substrate to immobilise the antibodies. Under the optimal conditions, the immunoassay exhibited high sensitivity, acceptable stability and reproducibility with a wide linear range from 0.001 to 100ngmL(-1) (R=0.996), and an ultra-low detection limit of 0.33pgmL(-1) (S/N=3). Furthermore, the immunosensor could be employed to detect SN in clinical serum samples. The proposed sensing strategy enriches the electrochemical immunoassay and exhibits potential for the point-of-care diagnostic application of the clinical screening of biomarkers.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Neuropeptídeos / Imunoensaio / Condutometria / Etilenodiaminas / Secretogranina II / Grafite / Chumbo Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Revista: Biosens Bioelectron Assunto da revista: BIOTECNOLOGIA Ano de publicação: 2015 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Neuropeptídeos / Imunoensaio / Condutometria / Etilenodiaminas / Secretogranina II / Grafite / Chumbo Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Revista: Biosens Bioelectron Assunto da revista: BIOTECNOLOGIA Ano de publicação: 2015 Tipo de documento: Article