Your browser doesn't support javascript.
loading
Evaluation of deformable image registration methods for dose monitoring in head and neck radiotherapy.
Rigaud, Bastien; Simon, Antoine; Castelli, Joël; Gobeli, Maxime; Ospina Arango, Juan-David; Cazoulat, Guillaume; Henry, Olivier; Haigron, Pascal; De Crevoisier, Renaud.
Afiliação
  • Rigaud B; Université de Rennes 1, LTSI, Campus de Beaulieu, 35000 Rennes, France ; INSERM, U1099, Campus de Beaulieu, 35000 Rennes, France.
  • Simon A; Université de Rennes 1, LTSI, Campus de Beaulieu, 35000 Rennes, France ; INSERM, U1099, Campus de Beaulieu, 35000 Rennes, France.
  • Castelli J; Université de Rennes 1, LTSI, Campus de Beaulieu, 35000 Rennes, France ; INSERM, U1099, Campus de Beaulieu, 35000 Rennes, France ; Centre Eugene Marquis, Radiotherapy Department, 35000 Rennes, France.
  • Gobeli M; Centre Eugene Marquis, Radiotherapy Department, 35000 Rennes, France.
  • Ospina Arango JD; Université de Rennes 1, LTSI, Campus de Beaulieu, 35000 Rennes, France ; INSERM, U1099, Campus de Beaulieu, 35000 Rennes, France.
  • Cazoulat G; Université de Rennes 1, LTSI, Campus de Beaulieu, 35000 Rennes, France ; INSERM, U1099, Campus de Beaulieu, 35000 Rennes, France.
  • Henry O; Centre Eugene Marquis, Radiotherapy Department, 35000 Rennes, France.
  • Haigron P; Université de Rennes 1, LTSI, Campus de Beaulieu, 35000 Rennes, France ; INSERM, U1099, Campus de Beaulieu, 35000 Rennes, France.
  • De Crevoisier R; Université de Rennes 1, LTSI, Campus de Beaulieu, 35000 Rennes, France ; INSERM, U1099, Campus de Beaulieu, 35000 Rennes, France ; Centre Eugene Marquis, Radiotherapy Department, 35000 Rennes, France.
Biomed Res Int ; 2015: 726268, 2015.
Article em En | MEDLINE | ID: mdl-25759821
ABSTRACT
In the context of head and neck cancer (HNC) adaptive radiation therapy (ART), the two purposes of the study were to compare the performance of multiple deformable image registration (DIR) methods and to quantify their impact for dose accumulation, in healthy structures. Fifteen HNC patients had a planning computed tomography (CT0) and weekly CTs during the 7 weeks of intensity-modulated radiation therapy (IMRT). Ten DIR approaches using different registration methods (demons or B-spline free form deformation (FFD)), preprocessing, and similarity metrics were tested. Two observers identified 14 landmarks (LM) on each CT-scan to compute LM registration error. The cumulated doses estimated by each method were compared. The two most effective DIR methods were the demons and the FFD, with both the mutual information (MI) metric and the filtered CTs. The corresponding LM registration accuracy (precision) was 2.44 mm (1.30 mm) and 2.54 mm (1.33 mm), respectively. The corresponding LM estimated cumulated dose accuracy (dose precision) was 0.85 Gy (0.93 Gy) and 0.88 Gy (0.95 Gy), respectively. The mean uncertainty (difference between maximal and minimal dose considering all the 10 methods) to estimate the cumulated mean dose to the parotid gland (PG) was 4.03 Gy (SD = 2.27 Gy, range 1.06-8.91 Gy).
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Monitoramento de Radiação / Neoplasias de Cabeça e Pescoço Limite: Aged / Aged80 / Humans / Middle aged Idioma: En Revista: Biomed Res Int Ano de publicação: 2015 Tipo de documento: Article País de afiliação: França País de publicação: EEUU / ESTADOS UNIDOS / ESTADOS UNIDOS DA AMERICA / EUA / UNITED STATES / UNITED STATES OF AMERICA / US / USA

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Monitoramento de Radiação / Neoplasias de Cabeça e Pescoço Limite: Aged / Aged80 / Humans / Middle aged Idioma: En Revista: Biomed Res Int Ano de publicação: 2015 Tipo de documento: Article País de afiliação: França País de publicação: EEUU / ESTADOS UNIDOS / ESTADOS UNIDOS DA AMERICA / EUA / UNITED STATES / UNITED STATES OF AMERICA / US / USA