Your browser doesn't support javascript.
loading
Graphics Processing Unit-Accelerated Nonrigid Registration of MR Images to CT Images During CT-Guided Percutaneous Liver Tumor Ablations.
Tokuda, Junichi; Plishker, William; Torabi, Meysam; Olubiyi, Olutayo I; Zaki, George; Tatli, Servet; Silverman, Stuart G; Shekher, Raj; Hata, Nobuhiko.
Afiliação
  • Tokuda J; Department of Radiology, Brigham and Women's Hospital and Harvard Medical School, 75 Francis St, ASB-I L1-050, Boston, MA 02115. Electronic address: tokuda@bwh.harvard.edu.
  • Plishker W; IGI Technologies, Inc., Elkridge, Maryland.
  • Torabi M; Department of Radiology, Brigham and Women's Hospital and Harvard Medical School, 75 Francis St, ASB-I L1-050, Boston, MA 02115.
  • Olubiyi OI; Department of Neurosurgery, Brigham and Women's Hospital and Harvard Medical School, Boston, Massachusetts.
  • Zaki G; IGI Technologies, Inc., Elkridge, Maryland.
  • Tatli S; Department of Radiology, Brigham and Women's Hospital and Harvard Medical School, 75 Francis St, ASB-I L1-050, Boston, MA 02115.
  • Silverman SG; Department of Radiology, Brigham and Women's Hospital and Harvard Medical School, 75 Francis St, ASB-I L1-050, Boston, MA 02115.
  • Shekher R; Children's National Medical Center, Washington, DC.
  • Hata N; Department of Radiology, Brigham and Women's Hospital and Harvard Medical School, 75 Francis St, ASB-I L1-050, Boston, MA 02115.
Acad Radiol ; 22(6): 722-33, 2015 Jun.
Article em En | MEDLINE | ID: mdl-25784325
RATIONALE AND OBJECTIVES: Accuracy and speed are essential for the intraprocedural nonrigid magnetic resonance (MR) to computed tomography (CT) image registration in the assessment of tumor margins during CT-guided liver tumor ablations. Although both accuracy and speed can be improved by limiting the registration to a region of interest (ROI), manual contouring of the ROI prolongs the registration process substantially. To achieve accurate and fast registration without the use of an ROI, we combined a nonrigid registration technique on the basis of volume subdivision with hardware acceleration using a graphics processing unit (GPU). We compared the registration accuracy and processing time of GPU-accelerated volume subdivision-based nonrigid registration technique to the conventional nonrigid B-spline registration technique. MATERIALS AND METHODS: Fourteen image data sets of preprocedural MR and intraprocedural CT images for percutaneous CT-guided liver tumor ablations were obtained. Each set of images was registered using the GPU-accelerated volume subdivision technique and the B-spline technique. Manual contouring of ROI was used only for the B-spline technique. Registration accuracies (Dice similarity coefficient [DSC] and 95% Hausdorff distance [HD]) and total processing time including contouring of ROIs and computation were compared using a paired Student t test. RESULTS: Accuracies of the GPU-accelerated registrations and B-spline registrations, respectively, were 88.3 ± 3.7% versus 89.3 ± 4.9% (P = .41) for DSC and 13.1 ± 5.2 versus 11.4 ± 6.3 mm (P = .15) for HD. Total processing time of the GPU-accelerated registration and B-spline registration techniques was 88 ± 14 versus 557 ± 116 seconds (P < .000000002), respectively; there was no significant difference in computation time despite the difference in the complexity of the algorithms (P = .71). CONCLUSIONS: The GPU-accelerated volume subdivision technique was as accurate as the B-spline technique and required significantly less processing time. The GPU-accelerated volume subdivision technique may enable the implementation of nonrigid registration into routine clinical practice.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Processamento de Imagem Assistida por Computador / Imageamento por Ressonância Magnética / Tomografia Computadorizada por Raios X / Radiografia Intervencionista / Ablação por Cateter / Neoplasias Hepáticas Tipo de estudo: Guideline / Observational_studies Limite: Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Acad Radiol Assunto da revista: RADIOLOGIA Ano de publicação: 2015 Tipo de documento: Article País de publicação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Processamento de Imagem Assistida por Computador / Imageamento por Ressonância Magnética / Tomografia Computadorizada por Raios X / Radiografia Intervencionista / Ablação por Cateter / Neoplasias Hepáticas Tipo de estudo: Guideline / Observational_studies Limite: Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Acad Radiol Assunto da revista: RADIOLOGIA Ano de publicação: 2015 Tipo de documento: Article País de publicação: Estados Unidos