Your browser doesn't support javascript.
loading
Drug-coated balloon dilation before carotid artery stenting of post-carotid endarterectomy restenosis.
Piccoli, Gianluca; Biondi-Zoccai, Giuseppe; Gavrilovic, Vladimir; Radici, Viviana; Cancelli, Iacopo; Frigatti, Paolo; Frati, Giacomo; Marullo, Antonino G M; Divis, Paolo; Gasparini, Daniele.
Afiliação
  • Piccoli G; S. Maria della Misericordia University Hospital, Udine, Italy piccoli.gianluca@gmail.com.
  • Biondi-Zoccai G; Sapienza University of Rome, Latina, Italy.
  • Gavrilovic V; S. Maria della Misericordia University Hospital, Udine, Italy.
  • Radici V; S. Maria della Misericordia University Hospital, Udine, Italy.
  • Cancelli I; S. Maria della Misericordia University Hospital, Udine, Italy.
  • Frigatti P; S. Maria della Misericordia University Hospital, Udine, Italy.
  • Frati G; Sapienza University of Rome, Latina, Italy IRCCS NeuroMed, Pozzilli, Italy.
  • Marullo AG; Sapienza University of Rome, Latina, Italy.
  • Divis P; S. Maria della Misericordia University Hospital, Udine, Italy.
  • Gasparini D; S. Maria della Misericordia University Hospital, Udine, Italy.
J Endovasc Ther ; 22(2): 212-6, 2015 Apr.
Article em En | MEDLINE | ID: mdl-25809364
ABSTRACT

PURPOSE:

To investigate if drug-coated balloon (DCB) predilation may improve the efficacy of carotid artery stenting (CAS) for restenosis after carotid endarterectomy (CEA).

METHODS:

Eighteen consecutive patients (11 men; median age 75 years) with significant restenosis within 24 months of CEA were treated with a paclitaxel-coated DCB prior to CAS. Clinical outcomes and stent patency were systematically appraised.

RESULTS:

All patients were successfully treated according to this clinical protocol. The only complication occurred in a patient who had a transient ischemic attack during prolonged DCB inflation. At a median follow-up of 18 months, no >50% restenosis was observed on duplex ultrasound scans; however, moderate hyperplasia at the proximal stent edge was found in 4 patients. One patient died at 9 months from a myocardial infarction.

CONCLUSION:

Despite the small sample size and in keeping with the historically high risk of recurrent restenosis after CAS for CEA restenosis, this case series suggests that DCB dilation followed by CAS for postsurgical restenosis is feasible, safe, and may be associated with favorable clinical outcomes at midterm follow-up.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fármacos Cardiovasculares / Endarterectomia das Carótidas / Estenose das Carótidas / Paclitaxel / Angioplastia com Balão / Materiais Revestidos Biocompatíveis / Dispositivos de Acesso Vascular Tipo de estudo: Diagnostic_studies / Guideline / Observational_studies / Risk_factors_studies Limite: Aged / Female / Humans / Male País/Região como assunto: Europa Idioma: En Revista: J Endovasc Ther Assunto da revista: ANGIOLOGIA Ano de publicação: 2015 Tipo de documento: Article País de afiliação: Itália

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fármacos Cardiovasculares / Endarterectomia das Carótidas / Estenose das Carótidas / Paclitaxel / Angioplastia com Balão / Materiais Revestidos Biocompatíveis / Dispositivos de Acesso Vascular Tipo de estudo: Diagnostic_studies / Guideline / Observational_studies / Risk_factors_studies Limite: Aged / Female / Humans / Male País/Região como assunto: Europa Idioma: En Revista: J Endovasc Ther Assunto da revista: ANGIOLOGIA Ano de publicação: 2015 Tipo de documento: Article País de afiliação: Itália
...