Your browser doesn't support javascript.
loading
The in vivo Pig-a assay: A report of the International Workshop On Genotoxicity Testing (IWGT) Workgroup.
Gollapudi, B Bhaskar; Lynch, Anthony M; Heflich, Robert H; Dertinger, Stephen D; Dobrovolsky, Vasily N; Froetschl, Roland; Horibata, Katsuyoshi; Kenyon, Michelle O; Kimoto, Takafumi; Lovell, David P; Stankowski, Leon F; White, Paul A; Witt, Kristine L; Tanir, Jennifer Y.
Afiliação
  • Gollapudi BB; E(x)ponent , Midland, MI, USA.
  • Lynch AM; GlaxoSmithKline, Hertfordshire, UK.
  • Heflich RH; US Food and Drug Administration, National Center for Toxicological Research, Jefferson, AR, USA. Electronic address: robert.heflich@fda.hhs.gov.
  • Dertinger SD; Litron Laboratories, Rochester, NY, USA.
  • Dobrovolsky VN; US Food and Drug Administration, National Center for Toxicological Research, Jefferson, AR, USA.
  • Froetschl R; Federal Institute for Drugs and Medical Devices, Bonn, Germany.
  • Horibata K; National Institute of Health Sciences, Tokyo, Japan.
  • Kenyon MO; Pfizer Global Research and Development, Groton, CT, USA.
  • Kimoto T; Teijin Pharma, Tokyo, Japan.
  • Lovell DP; St. George's, University of London, UK.
  • Stankowski LF; BioReliance, Rockville, MD, USA.
  • White PA; Environmental Health Science and Research Bureau, Health Canada, Ottawa, ON, Canada.
  • Witt KL; National Institutes of Health, National Institute of Environmental Health Sciences, Division of the National Toxicology Program, Research Triangle Park, NC, USA.
  • Tanir JY; Health and Environmental Sciences Institute, Washington, DC, USA.
Article em En | MEDLINE | ID: mdl-25953398
The in vivo Pig-a assay uses flow cytometry to measure phenotypic variants for antibody binding to cell surface glycosylphosphatidylinositol (GPI)-anchored proteins. There is good evidence suggesting that the absence of antibody binding is the result of a mutation in the endogenous X-linked Pig-a gene, which forms the rationale for the assay. Although the assay has been performed with several types of hematopoietic cells and in a variety of mammalian species, including humans, currently it is optimized only for measuring CD59-deficient (presumed Pig-a mutant) erythrocytes in the peripheral blood of rats. An expert workgroup formed by the International Workshop on Genotoxicity Testing considered the state of assay development and the potential of the assay for regulatory use. Consensus was reached on what is known about the Pig-a assay and how it should be conducted, and recommendations were made on additional data and refinements that would help to further enhance the assay for use in hazard identification and risk assessment.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Eritrócitos / Citometria de Fluxo / Hemoglobinúria / Anemia Hemolítica / Proteínas de Membrana / Mutação Tipo de estudo: Prognostic_studies / Risk_factors_studies Limite: Animals / Humans Idioma: En Revista: Mutat Res Genet Toxicol Environ Mutagen Ano de publicação: 2015 Tipo de documento: Article País de afiliação: Estados Unidos País de publicação: Holanda

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Eritrócitos / Citometria de Fluxo / Hemoglobinúria / Anemia Hemolítica / Proteínas de Membrana / Mutação Tipo de estudo: Prognostic_studies / Risk_factors_studies Limite: Animals / Humans Idioma: En Revista: Mutat Res Genet Toxicol Environ Mutagen Ano de publicação: 2015 Tipo de documento: Article País de afiliação: Estados Unidos País de publicação: Holanda