Your browser doesn't support javascript.
loading
Evaluation of cardiovascular changes in dogs administered three positive controls using jacketed external telemetry-blood pressure (JET-BP).
Kremer, John J; Bills, Andrew J; Hanke, Nathanael J; Chen, Hepei; Meier, William A; Osinski, Mark A; Foley, C Michael.
Afiliação
  • Kremer JJ; Covance Laboratories Inc., 3301 Kinsman Boulevard, Madison, WI 53704-2523, USA. Electronic address: john.kremer@covance.com.
  • Bills AJ; Covance Laboratories Inc., 3301 Kinsman Boulevard, Madison, WI 53704-2523, USA.
  • Hanke NJ; Covance Laboratories Inc., 3301 Kinsman Boulevard, Madison, WI 53704-2523, USA.
  • Chen H; Covance Laboratories Inc., 3301 Kinsman Boulevard, Madison, WI 53704-2523, USA.
  • Meier WA; Covance Laboratories Inc., 3301 Kinsman Boulevard, Madison, WI 53704-2523, USA.
  • Osinski MA; Covance Laboratories Inc., 3301 Kinsman Boulevard, Madison, WI 53704-2523, USA.
  • Foley CM; Covance Laboratories Inc., 3301 Kinsman Boulevard, Madison, WI 53704-2523, USA.
Article em En | MEDLINE | ID: mdl-26001324
ABSTRACT

INTRODUCTION:

Nonclinical safety studies are increasingly incorporating cardiac safety endpoints to discover potential cardiovascular liabilities. This trend for more thorough cardiovascular nonclinical safety evaluation is prudent given the high attrition rate of potential therapeutics due to unexpected cardiovascular liabilities discovered in late-stage clinical trials or post-market approval. In particular, the causal relationship of blood pressure changes that lead to risk of major adverse cardiac events suggests hemodynamic changes should be critically evaluated in preclinical studies of novel therapeutics.

METHODS:

Jacketed external telemetry with an implanted miniature blood pressure transmitter (JET-BP) was used to characterize the tolerability, functionality, and sensitivity of this study design in dogs. Thirty-six male or female beagles (n=6 dogs/sex/group) were administered vehicle control (reverse osmosis water) or etilefrine (1, 10mg/kg), sotalol (3, 30mg/kg), and hydralazine (1, 10mg/kg) on separate days. Telemetry data were evaluated for positive control article-related changes and retrospective power analysis was also completed. Animals were evaluated for instrumentation-related changes in clinical and anatomic pathology endpoints.

RESULTS:

All three positive controls elicited the expected pharmacologic responses that were statistically different at high and low doses. Retrospective power analysis confirmed this study design was able to statistically differentiate minor (approximately 5 to 15%) changes in electrocardiography and blood pressure values. This study also demonstrated the potential advantages of combining cardiovascular data across sex when the test article exposure and pharmacodynamics were consistent. Data collection using miniature telemetry blood pressure transmitters did not result in anatomic or clinical pathology findings that would prevent their use in general toxicology studies.

DISCUSSION:

This characterization study indicates that JET-BP in dogs offers a scientifically-robust method to evaluate novel therapeutics for potential cardiovascular liabilities.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Telemetria / Pressão Sanguínea / Avaliação Pré-Clínica de Medicamentos / Cardiotoxicidade Limite: Animals Idioma: En Revista: J Pharmacol Toxicol Methods Assunto da revista: FARMACOLOGIA / TOXICOLOGIA Ano de publicação: 2015 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Telemetria / Pressão Sanguínea / Avaliação Pré-Clínica de Medicamentos / Cardiotoxicidade Limite: Animals Idioma: En Revista: J Pharmacol Toxicol Methods Assunto da revista: FARMACOLOGIA / TOXICOLOGIA Ano de publicação: 2015 Tipo de documento: Article