Your browser doesn't support javascript.
loading
HPLC-UV method validation for the identification and quantification of bioactive amines in commercial eggs.
de Figueiredo, Tadeu Chaves; de Assis, Débora Cristina Sampaio; Menezes, Liliane Denize Miranda; da Silva, Guilherme Resende; Lanza, Isabela Pereira; Heneine, Luiz Guilherme Dias; Cançado, Silvana de Vasconcelos.
Afiliação
  • de Figueiredo TC; Escola de Veterinária, Universidade Federal de Minas Gerais (UFMG), Avenida Antônio Carlos, 6627, Belo Horizonte 30.123-970, Brazil.
  • de Assis DC; Escola de Veterinária, Universidade Federal de Minas Gerais (UFMG), Avenida Antônio Carlos, 6627, Belo Horizonte 30.123-970, Brazil.
  • Menezes LD; Instituto Mineiro de Agropecuária (IMA), Rodovia Américo Gianetti, 4001, Belo Horizonte 31.630-901, Brazil.
  • da Silva GR; Escola de Veterinária, Universidade Federal de Minas Gerais (UFMG), Avenida Antônio Carlos, 6627, Belo Horizonte 30.123-970, Brazil.
  • Lanza IP; Escola de Veterinária, Universidade Federal de Minas Gerais (UFMG), Avenida Antônio Carlos, 6627, Belo Horizonte 30.123-970, Brazil.
  • Heneine LG; Laboratório de Imunologia Aplicada, Fundação Ezequiel Dias (FUNED), Rua Conde Pereira Carneiro, 80, Belo Horizonte 30.510-010, Brazil.
  • Cançado Sde V; Escola de Veterinária, Universidade Federal de Minas Gerais (UFMG), Avenida Antônio Carlos, 6627, Belo Horizonte 30.123-970, Brazil. Electronic address: silvanavc@ufmg.br.
Talanta ; 142: 240-5, 2015 Sep 01.
Article em En | MEDLINE | ID: mdl-26003718
A quantitative and confirmatory high-performance liquid chromatography with ultraviolet detection (HPLC-UV) method for the determination of bioactive amines in the albumen and yolk of commercial eggs was developed, optimized and validated by analyte extraction with trichloroacetic acid and pre-column derivatization with dansyl chloride. Phenylethylamine, putrescine, cadaverine, histamine, tyramine, spermidine and spermine standards were used to evaluate the following performance parameters: limit of detection (LoD), limit of quantification (LoQ), selectivity, linearity, precision, recovery and ruggedness. The LoD of the method was defined from 0.2 to 0.3 mg kg(-1) for the yolk matrix and from 0.2 to 0.4 mg kg(-1) for the albumen matrix; the LoQ was from 0.7 to 1.0 mg kg(-1) for the yolk matrix and from 0.7 to 1.1 mg kg(-1) for the albumen matrix. The validated method exhibited excellent selectivity and separation of all amines with coefficients of determination higher than 0.99. The obtained recovery values were from 90.5% to 108.3%, and the relative standard deviation (RSD) was lower than 10% under repeatability conditions for the studied analytes. The performance parameters show the validated method to be adequate for the determination of bioactive amines in egg albumen and yolk.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fenetilaminas / Aminas Biogênicas / Albuminas / Gema de Ovo Tipo de estudo: Diagnostic_studies Idioma: En Revista: Talanta Ano de publicação: 2015 Tipo de documento: Article País de afiliação: Brasil País de publicação: Holanda

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fenetilaminas / Aminas Biogênicas / Albuminas / Gema de Ovo Tipo de estudo: Diagnostic_studies Idioma: En Revista: Talanta Ano de publicação: 2015 Tipo de documento: Article País de afiliação: Brasil País de publicação: Holanda