Determination of exifone in human plasma and urine by high-performance liquid chromatography with electrochemical detection.
J Chromatogr
; 496(2): 345-53, 1989 Nov 24.
Article
em En
| MEDLINE
| ID: mdl-2613838
A high-performance liquid chromatographic method with electrochemical detection was developed for the determination of exifone in human plasma and urine. Exifone was extracted from acidified plasma or neutralized urine with diethyl ether and the evaporated extracts were analysed on a C18 reversed-phase column. The compound was eluted in about 8 min with acetonitrile-0.3 M orthophosphoric acid (15:85, v/v) at a flow-rate of 0.9 ml/min. This method gave accurate and reproducible results; the calibration graphs were linear (r greater than 0.99) over the range of 2.8-360 nmol/l for plasma and 0.18-36 mumol/l for urine, and concentrations as low as 1 nmol/l in plasma could be quantified. These results allowed this assay to be used for determinations in single-dose pharmacokinetic studies.
Buscar no Google
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Psicotrópicos
/
Benzofenonas
Tipo de estudo:
Diagnostic_studies
Limite:
Humans
Idioma:
En
Revista:
J Chromatogr
Ano de publicação:
1989
Tipo de documento:
Article
País de afiliação:
França
País de publicação:
Holanda