Your browser doesn't support javascript.
loading
Design of multi-area grating for soft x-ray flat-field spectrograph.
Appl Opt ; 54(18): 5675-9, 2015 Jun 20.
Article em En | MEDLINE | ID: mdl-26193013
ABSTRACT
A soft x-ray flat-field grating with a nominal groove density of 2400 grooves/mm is typically used in wavelengths of 1-6 nm or 1-7 nm for plasma diagnostics. However, measurement of wavelengths even down to 0.6 nm simultaneously is expected in practice. Unfortunately, a grating has a poor spectral image at wavelengths below 1.3 nm. In order to improve the spectral image at lower wavelengths, multi-area gratings (divided perpendicular to the direction of grating grooves) are devised. To reduce the contribution of certain areas with poor spectral image to the final spectral image, the profile parameters of groove on the area are optimized by suppressing spectral efficiency. Theoretical analysis demonstrates that, using multi-area gratings, the spectral image at lower wavelengths could be obviously improved; thus, the spectral resolving power at a wavelength of 0.7 nm is increased from 94 to 398.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Appl Opt Ano de publicação: 2015 Tipo de documento: Article