Your browser doesn't support javascript.
loading
Silicon detectors for monitoring neutron beams in n-TOF beamlines.
Cosentino, L; Musumarra, A; Barbagallo, M; Colonna, N; Damone, L; Pappalardo, A; Piscopo, M; Finocchiaro, P.
Afiliação
  • Cosentino L; INFN Laboratori Nazionali del Sud, Catania, Italy.
  • Musumarra A; INFN Laboratori Nazionali del Sud, Catania, Italy.
  • Barbagallo M; INFN Sezione di Bari, Bari, Italy.
  • Colonna N; INFN Sezione di Bari, Bari, Italy.
  • Damone L; INFN Sezione di Bari, Bari, Italy.
  • Pappalardo A; INFN Laboratori Nazionali del Sud, Catania, Italy.
  • Piscopo M; INFN Laboratori Nazionali del Sud, Catania, Italy.
  • Finocchiaro P; INFN Laboratori Nazionali del Sud, Catania, Italy.
Rev Sci Instrum ; 86(7): 073509, 2015 Jul.
Article em En | MEDLINE | ID: mdl-26233385
ABSTRACT
During 2014, the second experimental area (EAR2) was completed at the n-TOF neutron beam facility at CERN (n-TOF indicates neutron beam measurements by means of time of flight technique). The neutrons are produced via spallation, by means of a high-intensity 20 GeV pulsed proton beam impinging on a thick target. The resulting neutron beam covers the energy range from thermal to several GeV. In this paper, we describe two beam diagnostic devices, both exploiting silicon detectors coupled with neutron converter foils containing (6)Li. The first one is based on four silicon pads and allows monitoring of the neutron beam flux as a function of the neutron energy. The second one, in beam and based on position sensitive silicon detectors, is intended for the reconstruction of the beam profile, again as a function of the neutron energy. Several electronic setups have been explored in order to overcome the issues related to the gamma flash, namely, a huge pulse present at the start of each neutron bunch which may blind the detectors for some time. The two devices were characterized with radioactive sources and also tested at the n-TOF facility at CERN. The wide energy and intensity range they proved capable of sustaining made them attractive and suitable to be used in both EAR1 and EAR2 n-TOF experimental areas, where they became immediately operational.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Rev Sci Instrum Ano de publicação: 2015 Tipo de documento: Article País de afiliação: Itália

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Rev Sci Instrum Ano de publicação: 2015 Tipo de documento: Article País de afiliação: Itália