Chiral Separation of Ormeloxifene Hydrochloride, a Non-steroidal Contraceptive Agent.
Ahmad, Hafsa; Gupta, Varsha; Dwivedi, Atma Prakash; Katti, S B; Dwivedi, Anil Kumar.
Afiliação
  • Ahmad H; Division of Pharmaceutics, Central Drug Research Institute, BS 10/1, Sector 10, Jankipuram Extension, Sitapur Road, Lucknow 226021, India.
  • Gupta V; Division of Pharmaceutics, Central Drug Research Institute, BS 10/1, Sector 10, Jankipuram Extension, Sitapur Road, Lucknow 226021, India.
  • Dwivedi AP; Division of Medicinal and Process Chemistry, Central Drug Research Institute, BS 10/1, Sector 10, Jankipuram Extension, Sitapur Road, Lucknow 226021, India.
  • Katti SB; Division of Medicinal and Process Chemistry, Central Drug Research Institute, BS 10/1, Sector 10, Jankipuram Extension, Sitapur Road, Lucknow 226021, India.
  • Dwivedi AK; Division of Pharmaceutics, Central Drug Research Institute, BS 10/1, Sector 10, Jankipuram Extension, Sitapur Road, Lucknow 226021, India anilcdri@gmail.com.
J Chromatogr Sci ; 54(2): 125-9, 2016 Feb.
Article em En | MEDLINE | ID: mdl-26233489
Ormeloxifene hydrochloride (Centchroman) is once-a-week non-steroidal oral contraceptive agent marketed in India and other countries. In this study, we report a validated isocratic high-performance liquid chromatographic (HPLC) method for chiral separation of D- and L-ormeloxifene hydrochloride. This method is capable of baseline separation of its D- and L-isomers. HPLC separation was achieved on a Lux 5µ cellulose-1 with a mobile phase comprising hexane, isopropanol, methanol and triethylamine (90:10:1:0.5). Validation parameters such as limit of detection, limit of quantitation, linearity, precision, accuracy, specificity and preformulation studies were conducted according to new guidelines of International Conference on Harmonization.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Benzopiranos / Cromatografia Líquida de Alta Pressão / Anticoncepcionais Tipo de estudo: Evaluation_studies Idioma: En Revista: J Chromatogr Sci Ano de publicação: 2016 Tipo de documento: Article País de afiliação: Índia País de publicação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Benzopiranos / Cromatografia Líquida de Alta Pressão / Anticoncepcionais Tipo de estudo: Evaluation_studies Idioma: En Revista: J Chromatogr Sci Ano de publicação: 2016 Tipo de documento: Article País de afiliação: Índia País de publicação: Estados Unidos