Your browser doesn't support javascript.
loading
[Evaluation of Storage Performance of Preserving Bags for Manually Separated Platelets].
Liu, Min-Xia; Duan, Lan; Wang, Jie-Xi; Wang, Yan; Zhuo, Hai-Long; Cai, Li-Na; Yi, Xiao-Yang; Zhou, Jian-Wei; Ang, Jian-Wei; Han, Ying.
Afiliação
  • Liu MX; Institute of Transfusion Medicine, Academy of Military Medical Sciences, Beijing 100850, China.
  • Duan L; Beijing Red Cross Blood Center, Beijing 100088, China.
  • Wang JX; Institute of Transfusion Medicine, Academy of Military Medical Sciences, Beijing 100850, China.
  • Wang Y; Institute of Transfusion Medicine, Academy of Military Medical Sciences, Beijing 100850, China.
  • Zhuo HL; Department of Blood Transfusion, Chinese PLA Hospital 307, Beijing 100071, China.
  • Cai LN; Institute of Transfusion Medicine, Academy of Military Medical Sciences, Beijing 100850, China.
  • Yi XY; Institute of Transfusion Medicine, Academy of Military Medical Sciences, Beijing 100850, China.
  • Zhou JW; Institute of Transfusion Medicine, Academy of Military Medical Sciences, Beijing 100850, China.
  • Ang JW; Shandong Weigao Group Medical Polymer Co. Ltd, Weihai 264209, Shandong Province, China.
  • Han Y; Institute of Transfusion Medicine, Academy of Military Medical Sciences, Beijing 100850, China. E-mall: hanying_1001@126.com.
Zhongguo Shi Yan Xue Ye Xue Za Zhi ; 23(4): 1152-5, 2015 Aug.
Article em Zh | MEDLINE | ID: mdl-26314463
OBJECTIVE: To evaluate the storage performance of the domestically made platelet storage bags (experimental group) and the United States Trima set platelet storage bags (control group). METHODS: The manually separated platelets were divided in two equal parts, which was added to control blood bags and experimental blood bags respectively, all samples were stored at a 22 °C ± 2 °C. The platelet count, mean volume, aggregation activity (ADP, THR), pH, glucose, lactate concentration, lactate dehydrogenase concentration, hypotonic shock reaction, CD62P and phosphatidic acid serine content were detected at day 0, 3, 5 and 7 of storage. RESULTS: There was no significant difference of platelet quality at day 5 after storage between the experimental group and the control group (T-test, P > 0.05). CONCLUSION: Two kinds of platelet storage bags have the similar storage performance.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Plaquetas / Preservação de Sangue / Separação Celular Limite: Humans Idioma: Zh Revista: Zhongguo Shi Yan Xue Ye Xue Za Zhi Assunto da revista: HEMATOLOGIA Ano de publicação: 2015 Tipo de documento: Article País de afiliação: China País de publicação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Plaquetas / Preservação de Sangue / Separação Celular Limite: Humans Idioma: Zh Revista: Zhongguo Shi Yan Xue Ye Xue Za Zhi Assunto da revista: HEMATOLOGIA Ano de publicação: 2015 Tipo de documento: Article País de afiliação: China País de publicação: China