Your browser doesn't support javascript.
loading
A comparative study on the mechanical behavior of polyurethane PICCs.
Poli, Paolo; Scocca, Antonella; Di Puccio, Francesca; Gallone, Giuseppe; Angelini, Lorenza; Calabrò, Emanuele Maria.
Afiliação
  • Poli P; Pain Therapy Unit, S. Chiara Hospital, Pisa - Italy.
  • Scocca A; Pain Therapy Unit, S. Chiara Hospital, Pisa - Italy.
  • Di Puccio F; Department of Civil and Industrial Engineering, University of Pisa, Pisa - Italy.
  • Gallone G; Department of Civil and Industrial Engineering, University of Pisa, Pisa - Italy.
  • Angelini L; Department of Civil and Industrial Engineering, University of Pisa, Pisa - Italy.
  • Calabrò EM; Department of Civil and Industrial Engineering, University of Pisa, Pisa - Italy.
J Vasc Access ; 17(2): 175-81, 2016.
Article em En | MEDLINE | ID: mdl-26349887
PURPOSE: This study describes a comparative analysis of eight commercial polyurethane, single-lumen peripherally inserted central venous catheters (PICCs) from different vendors. The aim was to investigate the mechanical response of the catheters providing objective and quantitative data to support a comparison among them. Such data could help nurses and physicians to select a central venous catheter (CVC) not only on the basis of the expected dwell duration or of the assessment of the vessels at the desired insertion site but also of the chemical and mechanical properties of the CVC and of the projected response of the body to these properties. METHODS: An experimental procedure was defined and tests were performed to assess some main characteristics of the PICC lines, including macro and microgeometric features, chemical and physical properties, and mechanical response. Preliminary measurements were performed to accurately define all geometric characteristics, including length, inner and outer diameters, and any inherent initial curvature of the catheter. Micro-geometric features were investigated using surface roughness analysis, optical microscopy, and scanning electron microscopy. Mechanical properties were studied by means of dynamic mechanical thermal analysis, simple uniaxial tensile tests, and kinking tests. RESULTS: Results are discussed in order to compare the different PICC lines. In particular, they show that polyurethane catheters can have a different mechanical behavior, which might play a role in the onset of pathologic processes and result in an increased risk and incidence of catheter-related complications. CONCLUSIONS: This study provides useful information that can help identifying and facilitate the choice of a PICC.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Poliuretanos / Cateterismo Periférico / Cateteres de Demora / Cateteres Venosos Centrais Tipo de estudo: Prognostic_studies Limite: Humans Idioma: En Revista: J Vasc Access Assunto da revista: ANGIOLOGIA Ano de publicação: 2016 Tipo de documento: Article País de publicação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Poliuretanos / Cateterismo Periférico / Cateteres de Demora / Cateteres Venosos Centrais Tipo de estudo: Prognostic_studies Limite: Humans Idioma: En Revista: J Vasc Access Assunto da revista: ANGIOLOGIA Ano de publicação: 2016 Tipo de documento: Article País de publicação: Estados Unidos