Usefulness of multislice-CT using multiplanar reconstruction in the preoperative assessment of the ossicular lesions in the middle ear diseases.
Fujiwara, Seiko; Toyama, Yoshihiro; Miyashita, Takenori; Osaki, Yasuhiro; Inamoto, Ryuhei; Hoshikawa, Hiroshi; Mori, Nozomu.
Afiliação
  • Fujiwara S; Department of Otolaryngology, Faculty of Medicine, Kagawa University, Kagawa, Japan. Electronic address: spring@kms.ac.jp.
  • Toyama Y; Department of Radiology, Takamatsu Redcross Hospital, Kagawa, Japan.
  • Miyashita T; Department of Otolaryngology, Faculty of Medicine, Kagawa University, Kagawa, Japan.
  • Osaki Y; Department of Otolaryngology, Osaka Medical Center And Research Institute For Maternal and Child Health, Osaka, Japan.
  • Inamoto R; Department of Otolaryngology, Faculty of Medicine, Kagawa University, Kagawa, Japan.
  • Hoshikawa H; Department of Otolaryngology, Faculty of Medicine, Kagawa University, Kagawa, Japan.
  • Mori N; Department of Otolaryngology, Faculty of Medicine, Kagawa University, Kagawa, Japan; Osaka Bay Central Hospital, Osaka, Japan.
Auris Nasus Larynx ; 43(3): 247-53, 2016 Jun.
Article em En | MEDLINE | ID: mdl-26386497
ABSTRACT

OBJECTIVE:

The aim of the study is to evaluate the usefulness of multislice computed tomography (MSCT) using multiplanar reconstruction (MPR) in obtaining preoperative information on the ossicular lesions of middle ear diseases by comparing the ossicular findings of MPR images with the operative findings.

METHODS:

Sixty-two ears and 10 ears with preoperative middle ear diseases underwent 4- and 64-detector row CT of the temporal bone in Kagawa University Hospital, respectively. MPR images of three ossicles were created at the planes parallel to the long axis of ossicles.

RESULTS:

The findings of the three ossicles in MPR images were compatible with their operative findings in approximately 91% of 72 ears with various middle ear diseases. There was no significant difference in the coincidence rate of both findings between 4- and 64-detector row CT scanners. The ears with no soft tissue shadows around the ossicles had the coincidence rate of 96-100% in each ossicular part, whereas the coincidence rate was lower in the ears with soft tissue shadows around the ossicles.

CONCLUSION:

MPR imagings of the ossicles provide accurate preoperative information on the ossicular lesions in middle ear diseases. The 4-detector CT is still a useful device for imaging of the ossicles.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Otite Média / Colesteatoma da Orelha Média / Orelha Média / Ossículos da Orelha Limite: Adolescent / Adult / Aged / Child / Child, preschool / Female / Humans / Male / Middle aged Idioma: En Revista: Auris Nasus Larynx Ano de publicação: 2016 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Otite Média / Colesteatoma da Orelha Média / Orelha Média / Ossículos da Orelha Limite: Adolescent / Adult / Aged / Child / Child, preschool / Female / Humans / Male / Middle aged Idioma: En Revista: Auris Nasus Larynx Ano de publicação: 2016 Tipo de documento: Article