Mass spectrometric imaging of brain tissue by time-of-flight secondary ion mass spectrometry--How do polyatomic primary beams C60⁺, Ar2000⁺, water-doped Ar2000⁺ and (H2O)6000⁺ compare?
Razo, Irma Berrueta; Sheraz, Sadia née Rabbani; Henderson, Alex; Lockyer, Nicholas P; Vickerman, John C.
Afiliação
  • Razo IB; Manchester Institute of Biotechnology, The University of Manchester, Manchester, M13 9PL, UK.
  • Sheraz Sn; School of Chemistry, The University of Manchester, Manchester, UK.
  • Henderson A; Manchester Institute of Biotechnology, The University of Manchester, Manchester, M13 9PL, UK.
  • Lockyer NP; School of Chemical Engineering and Analytical Science, The University of Manchester, Manchester, UK.
  • Vickerman JC; Manchester Institute of Biotechnology, The University of Manchester, Manchester, M13 9PL, UK.
Rapid Commun Mass Spectrom ; 29(20): 1851-62, 2015 Oct 30.
Article em En | MEDLINE | ID: mdl-26411506
RATIONALE: To discover the degree to which water-containing cluster beams increase secondary ion yield and reduce the matrix effect in time-of-flight secondary ion mass spectrometry (TOF-SIMS) imaging of biological tissue. METHODS: The positive SIMS ion yields from model compounds, mouse brain lipid extract and mouse brain tissue together with mouse brain images were compared using 20 keV C60(+), Ar2000(+), water-doped Ar2000(+) and pure (H2O)6000(+) primary beams. RESULTS: Water-containing cluster beams where the beam energy per nucleon (E/nucleon) ≈ 0.2 eV are optimum for enhancing ion yields dependent on protonation. Ion yield enhancements over those observed using Ar2000(+) lie in the range 10 to >100 using the (H2 O)6000 (+) beam, while with water-doped (H2O)Ar2000(+) they lie in the 4 to 10 range. The two water-containing beams appear to be optimum for tissue imaging and show strong evidence of increasing yields from molecules that experience matrix suppression under other primary beams. CONCLUSIONS: The application of water-containing primary beams is suggested for biological SIMS imaging applications, particularly if the beam energy can be raised to 40 keV or higher to further increase ion yield and enhance spatial resolution to ≤1 µm.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Química Encefálica / Espectrometria de Massa de Íon Secundário Tipo de estudo: Evaluation_studies Limite: Animals Idioma: En Revista: Rapid Commun Mass Spectrom Ano de publicação: 2015 Tipo de documento: Article País de publicação: Reino Unido

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Química Encefálica / Espectrometria de Massa de Íon Secundário Tipo de estudo: Evaluation_studies Limite: Animals Idioma: En Revista: Rapid Commun Mass Spectrom Ano de publicação: 2015 Tipo de documento: Article País de publicação: Reino Unido