Your browser doesn't support javascript.
loading
Reagent for Evaluating Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS) Performance in Bottom-Up Proteomic Experiments.
Beri, Joshua; Rosenblatt, Michael M; Strauss, Ethan; Urh, Marjeta; Bereman, Michael S.
Afiliação
  • Beri J; Department of Chemistry, North Carolina State University , Raleigh, North Carolina 27695, United States.
  • Rosenblatt MM; Promega Corporation, 2800 Woods Hollow Road, Madison, Wisconsin 53711, United States.
  • Strauss E; Promega Corporation, 2800 Woods Hollow Road, Madison, Wisconsin 53711, United States.
  • Urh M; Promega Corporation, 2800 Woods Hollow Road, Madison, Wisconsin 53711, United States.
  • Bereman MS; Department of Chemistry, North Carolina State University , Raleigh, North Carolina 27695, United States.
Anal Chem ; 87(23): 11635-40, 2015 Dec 01.
Article em En | MEDLINE | ID: mdl-26537636
ABSTRACT
We present a novel proteomic standard for assessing liquid chromatography-tandem mass spectrometry (LC-MS/MS) instrument performance, in terms of chromatographic reproducibility and dynamic range within a single LC-MS/MS injection. The peptide mixture standard consists of six peptides that were specifically synthesized to cover a wide range of hydrophobicities (grand average hydropathy (GRAVY) scores of -0.6 to 1.9). A combination of stable isotope labeled amino acids ((13)C and (15)N) were inserted to create five isotopologues. By combining these isotopologues at different ratios, they span four orders of magnitude within each distinct peptide sequence. Each peptide, from lightest to heaviest, increases in abundance by a factor of 10. We evaluate several metrics on our quadrupole orbitrap instrument using the 6 × 5 LC-MS/MS reference mixture spiked into a complex lysate background as a function of dynamic range, including mass measurement accuracy (MMA) and the linear range of quantitation of MS1 and parallel reaction monitoring experiments. Detection and linearity of the instrument routinely spanned three orders of magnitude across the gradient (500 fmol to 0.5 fmol on column) and no systematic trend was observed for MMA of targeted peptides as a function of abundance by analysis of variance analysis (p = 0.17). Detection and linearity of the fifth isotopologue (i.e., 0.05 fmol on column) was dependent on the peptide and instrument scan type (MS1 vs PRM). We foresee that this standard will serve as a powerful method to conduct both intra-instrument performance monitoring/evaluation, technology development, and inter-instrument comparisons.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Peptídeos / Cromatografia Líquida / Proteômica / Espectrometria de Massas em Tandem / Indicadores e Reagentes Limite: Humans Idioma: En Revista: Anal Chem Ano de publicação: 2015 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Peptídeos / Cromatografia Líquida / Proteômica / Espectrometria de Massas em Tandem / Indicadores e Reagentes Limite: Humans Idioma: En Revista: Anal Chem Ano de publicação: 2015 Tipo de documento: Article País de afiliação: Estados Unidos