Radionuclidic purity tests in (18)F radiopharmaceutIcals production process.
Appl Radiat Isot
; 109: 242-246, 2016 Mar.
Article
em En
| MEDLINE
| ID: mdl-26553157
Radionuclidic purity tests of (18)F radiopharmaceuticals (Na(18)F and fluorodeoxyglucose [(18)F]FDG) and radionuclide composition analysis of irradiated water [(18)O]H2O were performed. The measurements were conducted using a High-Purity Germanium (HPGe) detector and a liquid scintillation counter. Radionuclide identification and activity measurements were performed for samples from different stages of the production process. Most of the impurities were detected on QMA (quaternary methylammonium) anion exchange columns and in liquid wastes. Using liquid scintillation counting, the activity of (3)H resulting from the (18)O[p, (3)H](16)O reaction was determined. It was shown that all of the impurities were efficiently determined and eliminated in the radiopharmaceuticals synthesis process and that the final products meet the requirements set by relevant regulations.
Palavras-chave
Texto completo:
1
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Radiometria
/
Radioisótopos de Flúor
/
Contaminação de Medicamentos
/
Composição de Medicamentos
Tipo de estudo:
Diagnostic_studies
/
Prognostic_studies
País/Região como assunto:
Europa
Idioma:
En
Revista:
Appl Radiat Isot
Assunto da revista:
MEDICINA NUCLEAR
/
SAUDE AMBIENTAL
Ano de publicação:
2016
Tipo de documento:
Article
País de publicação:
Reino Unido