Your browser doesn't support javascript.
loading
Concentration of Sonication Fluid through Centrifugation Is Superior to Membrane Filtration for Microbial Diagnosis of Orthopedic Implant-Associated Infection.
Zitron, Renato; Wajsfeld, Tali; Klautau, Giselle Burlamaqui; da Silva, Cely Barreto; Nigro, Stanley; Mercadante, Marcelo Tomanik; Polesello, Giancarlo Cavalli; Cury, Ricardo de Paula Leite; Salles, Mauro Jose Costa.
Afiliação
  • Zitron R; Division of Infectious Diseases, Santa Casa de São Paulo School of Medical Sciences, São Paulo, Brazil Department of Internal Medicine, Santa Casa de São Paulo School of Medical Sciences, São Paulo, Brazil.
  • Wajsfeld T; Division of Infectious Diseases, Santa Casa de São Paulo School of Medical Sciences, São Paulo, Brazil Department of Internal Medicine, Santa Casa de São Paulo School of Medical Sciences, São Paulo, Brazil.
  • Klautau GB; Division of Infectious Diseases, Santa Casa de São Paulo School of Medical Sciences, São Paulo, Brazil Department of Internal Medicine, Santa Casa de São Paulo School of Medical Sciences, São Paulo, Brazil.
  • da Silva CB; Department of Laboratory Medicine and Pathology, Santa Casa de São Paulo School of Medical Sciences, São Paulo, Brazil.
  • Nigro S; Department of Laboratory Medicine and Pathology, Santa Casa de São Paulo School of Medical Sciences, São Paulo, Brazil.
  • Mercadante MT; Department of Orthopedic Surgery, Santa Casa de São Paulo School of Medical Sciences, São Paulo, Brazil.
  • Polesello GC; Department of Orthopedic Surgery, Santa Casa de São Paulo School of Medical Sciences, São Paulo, Brazil.
  • Cury Rde P; Department of Orthopedic Surgery, Santa Casa de São Paulo School of Medical Sciences, São Paulo, Brazil.
  • Salles MJ; Division of Infectious Diseases, Santa Casa de São Paulo School of Medical Sciences, São Paulo, Brazil Department of Internal Medicine, Santa Casa de São Paulo School of Medical Sciences, São Paulo, Brazil mcsalles@osite.com.br.
J Clin Microbiol ; 54(3): 788-90, 2016 Mar.
Article em En | MEDLINE | ID: mdl-26719446

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Centrifugação / Técnicas Microbiológicas / Infecções Relacionadas à Prótese / Procedimentos Ortopédicos / Filtração Tipo de estudo: Diagnostic_studies / Prognostic_studies / Risk_factors_studies Limite: Adolescent / Adult / Aged / Aged80 / Child / Female / Humans / Male / Middle aged Idioma: En Revista: J Clin Microbiol Ano de publicação: 2016 Tipo de documento: Article País de afiliação: Brasil País de publicação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Centrifugação / Técnicas Microbiológicas / Infecções Relacionadas à Prótese / Procedimentos Ortopédicos / Filtração Tipo de estudo: Diagnostic_studies / Prognostic_studies / Risk_factors_studies Limite: Adolescent / Adult / Aged / Aged80 / Child / Female / Humans / Male / Middle aged Idioma: En Revista: J Clin Microbiol Ano de publicação: 2016 Tipo de documento: Article País de afiliação: Brasil País de publicação: Estados Unidos