Your browser doesn't support javascript.
loading
A Dual Tracer 18F-FCH/18F-FDG PET Imaging of an Orthotopic Brain Tumor Xenograft Model.
Fu, Yilong; Ong, Lai-Chun; Ranganath, Sudhir H; Zheng, Lin; Kee, Irene; Zhan, Wenbo; Yu, Sidney; Chow, Pierce K H; Wang, Chi-Hwa.
Afiliação
  • Fu Y; Department of Chemical and Biomolecular Engineering, National University of Singapore, 4 Engineering Drive 4, Singapore 117585, Singapore.
  • Ong LC; Department of Chemical and Biomolecular Engineering, National University of Singapore, 4 Engineering Drive 4, Singapore 117585, Singapore.
  • Ranganath SH; Department of Chemical and Biomolecular Engineering, National University of Singapore, 4 Engineering Drive 4, Singapore 117585, Singapore.
  • Zheng L; Department of Chemical Engineering, Siddaganga Institute of Technology, B.H. Road, Tumkur-572103, India.
  • Kee I; SingHealth Experimental Medicine Center, Singapore General Hospital, Block 9, Level 3, Outram Road, Singapore 169608, Singapore.
  • Zhan W; SingHealth Experimental Medicine Center, Singapore General Hospital, Block 9, Level 3, Outram Road, Singapore 169608, Singapore.
  • Yu S; NUS Environmental Research Institute, National University of Singapore, 1 Create Way, Create Tower #15-02, Singapore 138602, Singapore.
  • Chow PK; National Cancer Centre, 11 Hospital Drive, Singapore 169610, Singapore.
  • Wang CH; National Cancer Centre, 11 Hospital Drive, Singapore 169610, Singapore.
PLoS One ; 11(2): e0148123, 2016.
Article em En | MEDLINE | ID: mdl-26844770
Early diagnosis of low grade glioma has been a challenge to clinicians. Positron Emission Tomography (PET) using 18F-FDG as a radio-tracer has limited utility in this area because of the high background in normal brain tissue. Other radiotracers such as 18F-Fluorocholine (18F-FCH) could provide better contrast between tumor and normal brain tissue but with high incidence of false positives. In this study, the potential application of a dual tracer 18F-FCH/18F-FDG-PET is investigated in order to improve the sensitivity of PET imaging for low grade glioma diagnosis based on a mouse orthotopic xenograft model. BALB/c nude mice with and without orthotopic glioma xenografts from U87 MG-luc2 glioma cell line are used for the study. The animals are subjected to 18F-FCH and 18F-FDG PET imaging, and images acquired from two separate scans are superimposed for analysis. The 18F-FCH counts are subtracted from the merged images to identify the tumor. Micro-CT, bioluminescence imaging (BLI), histology and measurement of the tumor diameter are also conducted for comparison. Results show that there is a significant contrast in 18F-FCH uptake between tumor and normal brain tissue (2.65 ± 0.98), but with a high false positive rate of 28.6%. The difficulty of identifying the tumor by 18F-FDG only is also proved in this study. All the tumors can be detected based on the dual tracer technique of 18F-FCH/18F-FDG-PET imaging in this study, while the false-positive caused by 18F-FCH can be eliminated. Dual tracer 18F-FCH/18F-FDG PET imaging has the potential to improve the visualization of low grade glioma. 18F-FCH delineates tumor areas and the tumor can be identified by subtracting the 18F-FCH counts. The sensitivity was over 95%. Further studies are required to evaluate the possibility of applying this technique in clinical trials.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Neoplasias Encefálicas / Colina / Compostos Radiofarmacêuticos / Fluordesoxiglucose F18 / Tomografia por Emissão de Pósitrons Tipo de estudo: Screening_studies Limite: Animals / Humans Idioma: En Revista: PLoS One Assunto da revista: CIENCIA / MEDICINA Ano de publicação: 2016 Tipo de documento: Article País de afiliação: Singapura País de publicação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Neoplasias Encefálicas / Colina / Compostos Radiofarmacêuticos / Fluordesoxiglucose F18 / Tomografia por Emissão de Pósitrons Tipo de estudo: Screening_studies Limite: Animals / Humans Idioma: En Revista: PLoS One Assunto da revista: CIENCIA / MEDICINA Ano de publicação: 2016 Tipo de documento: Article País de afiliação: Singapura País de publicação: Estados Unidos